Sort by:
Page 291 of 6596585 results

McGhee KN, Barrett DJ, Safarini O, Elkassem AA, Eddins JT, Smith AD, Rothenberg SA

pubmed logopapersAug 7 2025
Artificial Intelligence (AI) is rapidly being implemented into clinical practice to improve diagnostic accuracy and reduce provider burnout. However, patient self-perceived knowledge and perceptions of AI's role in their care remain unclear. This study aims to explore patient preferences regarding the use of and communication of AI in their care for patients undergoing cross-sectional imaging exams. This single-center cross-sectional study, a structured questionnaire recruited patients undergoing outpatient CT or MRI examinations between June and July 2024 to assess baseline self-perceived knowledge of AI, perspectives on AI in clinical care, preferences regarding AI-generated results, and economic considerations related to AI, using Likert scales and categorical questions. A total of 226 participants (143 females; mean age 53 years) were surveyed with 67.4% (151/224) reporting having minimal to no knowledge of AI in medicine, with lower knowledge levels associated with lower socioeconomic status (p < .001). 90.3% (204/226) believed they should be informed about the use of AI in their care, and 91.1% (204/224) supported the right to opt out. Additionally, 91.1% (204/224) of participants expressed a strong preference for being informed when AI was involved in interpreting their medical images. 65.6% (143/218) indicated that they would not accept a screening imaging exam exclusively interpreted by an AI algorithm. Finally, 91.1% (204/224) of participants wanted disclosure when AI was used and 89.1% (196/220) felt such disclosure and clarification of discrepancies should be considered standard care. To align AI adoption with patient preferences and expectations, radiology practices must prioritize disclosure, patient engagement, and standardized documentation of AI use without being overly burdensome to the diagnostic workflow. Patients prefer transparency for AI utilization in their care, and our study highlights the discrepancy between patient preferences and current clinical practice. Patients are not expected to determine the technical aspects of an image examination such as acquisition parameters or reconstruction kernel and must trust their providers to act in their best interest. Clear communication of how AI is being used in their care should be provided in ways that do not overly burden the radiologist.

Nau MA, Nutricati LA, Camino B, Warburton PA, Maier AK

pubmed logopapersAug 7 2025
We investigate the use of quantum computing algorithms on real quantum hardware to tackle the computationally intensive task of feature selection for light-weight medical image datasets. Feature selection is often formulated as a k of n selection problem, where the complexity grows binomially with increasing k and n. Quantum computers, particularly quantum annealers, are well-suited for such problems, which may offer advantages under certain problem formulations. We present a method to solve larger feature selection instances than previously demonstrated on commercial quantum annealers. Our approach combines a linear Ising penalty mechanism with subsampling and thresholding techniques to enhance scalability. The method is tested in a toy problem where feature selection identifies pixel masks used to reconstruct small-scale medical images. We compare our approach against a range of feature selection strategies, including randomized baselines, classical supervised and unsupervised methods, combinatorial optimization via classical and quantum solvers, and learning-based feature representations. The results indicate that quantum annealing-based feature selection is effective for this simplified use case, demonstrating its potential in high-dimensional optimization tasks. However, its applicability to broader, real-world problems remains uncertain, given the current limitations of quantum computing hardware. While learned feature representations such as autoencoders achieve superior reconstruction performance, they do not offer the same level of interpretability or direct control over input feature selection as our approach.

Aghajanian S, Mohammadifard F, Mohammadi I, Rajai Firouzabadi S, Baradaran Bagheri A, Moases Ghaffary E, Mirmosayyeb O

pubmed logopapersAug 7 2025
Alzheimer's disease (AD) is the principal cause of dementia and requires the early diagnosis of people with mild cognitive impairment (MCI) who are at high risk of progressing. Early diagnosis is imperative for optimizing clinical management and selecting proper therapeutic interventions. Structural magnetic resonance imaging (MRI) markers have been widely investigated for predicting the conversion of MCI to AD, and recent advances in deep learning (DL) methods offer enhanced capabilities for identifying subtle neurodegenerative changes over time. We selected 228 MCI participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI) who had at least three T1-weighted MRI scans within 18 months of baseline. MRI volumes underwent bias correction, segmentation, and radiomics feature extraction. A 3D residual network (ResNet3D) was trained using a pairwise ranking loss to capture single-timepoint risk scores. Longitudinal analyses were performed by extracting deep convolutional neural network (CNN) embeddings and gray matter radiomics for each scan, which were put into a time-aware long short-term memory (LSTM) model with an attention mechanism. A single-timepoint ResNet3D model achieved modest performance (c-index ~ 0.70). Incorporating longitudinal MRI files or downstream survival models led to a pronounced prognostic improvement (c-index:0.80-0.90), but was not further improved by longitudinal radiomics data. Time-specific classification within two- and three-year and five-year windows after the last MRI acquisition showed high accuracy (AUC > 0.85). Several radiomics, including gray matter surface to volume and elongation, emerged as the most predictive features. Each SD change in the gray matter surface to volume change within the last visit was associated with an increased risk of developing AD (HR: 1.50; 95% CI: 1.25-1.79). These findings emphasize the value of structural MRI within the advanced DL architectures for predicting MCI-to-AD conversion. The approach may enable earlier risk stratification and targeted interventions for individuals most likely to progress. limitations in sample size and computational resources warrant larger, more diverse studies to confirm these observations and explore additional improvements.

Tran N, Luks TL, Li Y, Jakary A, Ellison J, Liu B, Adegbite O, Nair D, Kakhandiki P, Molinaro AM, Villanueva-Meyer JE, Butowski N, Clarke JL, Chang SM, Braunstein SE, Morin O, Lin H, Lupo JM

pubmed logopapersAug 7 2025
The current standard-of-care (SOC) practice for defining the clinical target volume (CTV) for radiation therapy (RT) in patients with glioblastoma still employs an isotropic 1-2 cm expansion of the T2-hyperintensity lesion, without considering the heterogeneous infiltrative nature of these tumors. This study aims to improve RT CTV definition in patients with glioblastoma by incorporating biologically relevant metabolic and physiologic imaging acquired before RT along with a deep learning model that can predict regions of subsequent tumor progression by either the presence of contrast-enhancement or T2-hyperintensity. The results were compared against two standard CTV definitions. Our multi-parametric deep learning model significantly outperformed the uniform 2 cm expansion of the T2-lesion CTV in terms of specificity (0.89 ± 0.05 vs 0.79 ± 0.11; p = 0.004), while also achieving comparable sensitivity (0.92 ± 0.11 vs 0.95 ± 0.08; p = 0.10), sparing more normal brain. Model performance was significantly enhanced by incorporating lesion size-weighted loss functions during training and including metabolic images as inputs.

Mc Laughlin O, Gholami F, Osman S, O'Sullivan JM, McMahon SJ, Jain S, McGarry CK

pubmed logopapersAug 7 2025
Objective&#xD;This study assesses rectum contours generated using a commercial deep learning auto-contouring model and compares them to clinician contours using geometry, changes in dosimetry and toxicity modelling. &#xD;Approach&#xD;This retrospective study involved 308 prostate cancer patients who were treated using 3D-conformal radiotherapy. Computed tomography images were input into Limbus Contour (v1.8.0b3) to generate auto-contour structures for each patient. Auto-contours were not edited after their generation.&#xD;Rectum auto-contours were compared to clinician contours geometrically and dosimetrically. Dice similarity coefficient (DSC), mean Hausdorff distance (HD) and volume difference were assessed. Dose-volume histogram (DVH) constraints (V41%-V100%) were compared, and a Wilcoxon signed rank test was used to evaluate statistical significance of differences. &#xD;Toxicity modelling to compare contours was carried out using equivalent uniform dose (EUD) and clinical factors of abdominal surgery and atrial fibrillation. Trained models were tested (80:20) in their prediction of grade 1 late rectal bleeding (ntotal=124) using area-under the receiver operating characteristic curve (AUC).&#xD;Main results&#xD;Median DSC (interquartile range (IQR)) was 0.85 (0.09), median HD was 1.38 mm (0.60 mm) and median volume difference was -1.73 cc (14.58 cc). Median DVH differences between contours were found to be small (<1.5%) for all constraints although systematically larger than clinician contours (p<0.05). However, an IQR up to 8.0% was seen for individual patients across all dose constraints.&#xD;Models using EUD alone derived from clinician or auto-contours had AUCs of 0.60 (0.10) and 0.60 (0.09). AUC for models involving clinical factors and dosimetry was 0.65 (0.09) and 0.66 (0.09) when using clinician contours and auto-contours.&#xD;Significance&#xD;Although median DVH metrics were similar, variation for individual patients highlights the importance of clinician review. Rectal bleeding prediction accuracy did not depend on the contour method for this cohort. The auto-contouring model used in this study shows promise in a supervised workflow.&#xD.

Jiang H, Zhang Q, Hu Y, Jin Y, Liu H, Chen Z, Yumo Z, Fan W, Zheng HR, Liang D, Hu Z

pubmed logopapersAug 7 2025
Reconstructing high-quality images from corrupted measurements remains a fundamental challenge in medical imaging. Recently, deep unrolling (DUN) methods have emerged as a promising solution, combining the interpretability of traditional iterative algorithms with the powerful representation capabilities of deep learning. However, their performance is often limited by weak information flow between iterative stages and a constrained ability to capture global features across stages-limitations that tend to worsen as the number of iterations increases.&#xD;Approach: In this work, we propose a memory-enhanced and multi-domain learning-based deep unrolling network for interpretable, high-fidelity medical image reconstruction. First, a memory-enhanced module is designed to adaptively integrate historical outputs across stages, reducing information loss. Second, we introduce a cross-stage spatial-domain learning transformer (CS-SLFormer) to extract both local and non-local features within and across stages, improving reconstruction performance. Finally, a frequency-domain consistency learning (FDCL) module ensures alignment between reconstructed and ground truth images in the frequency domain, recovering fine image details.&#xD;Main Results: Comprehensive experiments evaluated on three representative medical imaging modalities (PET, MRI, and CT) show that the proposed method consistently outperforms state-of-the-art (SOTA) approaches in both quantitative metrics and visual quality. Specifically, our method achieved a PSNR of 37.835 dB and an SSIM of 0.970 in 1 $\%$ dose PET reconstruction.&#xD;Significance: This study expands the use of model-driven deep learning in medical imaging, demonstrating the potential of memory-enhanced deep unrolling frameworks for high-quality reconstructions.

Matte Bon, G., Walther, J., Comasco, E., Derntl, B., Kaufmann, T.

medrxiv logopreprintAug 7 2025
Sex differences in mental health become more evident across adolescence, with a two-fold increase of prevalence of mood disorders in females compared to males. The brain underpinnings remain understudied. Here, we investigated the role of age, puberty and mental health in determining the longitudinal development of sex differences in brain structure. We captured sex differences in limbic and non-limbic structures using machine learning models trained in cross-sectional brain imaging data of 1132 youths, yielding limbic and non-limbic estimates of brain sex. Applied to two independent longitudinal samples (total: 8184 youths), our models revealed pronounced sex differences in brain structure with increasing age. For females, brain sex was sensitive to pubertal development (menarche) over time and, for limbic structures, to mood-related mental health. Our findings highlight the limbic system as a key contributor to the development of sex differences in the brain and the potential of machine learning models for brain sex classification to investigate sex-specific processes relevant to mental health.

Chen K, Hou X, Li X, Xu W, Yi H

pubmed logopapersAug 7 2025
The purpose of this study is to compare the performance of GPT-4 and DeepSeek large language models in generating structured breast cancer multimodality imaging integrated reports from free-text radiology reports including mammography, ultrasound, MRI, and PET/CT. A retrospective analysis was conducted on 1358 free-text reports from 501 breast cancer patients across two institutions. The study design involved synthesizing multimodal imaging data into structured reports with three components: primary lesion characteristics, metastatic lesions, and TNM staging. Input prompts were standardized for both models, with GPT-4 using predesigned instructions and DeepSeek requiring manual input. Reports were evaluated based on physician satisfaction using a Likert scale, descriptive accuracy including lesion localization, size, SUV, and metastasis assessment, and TNM staging correctness according to NCCN guidelines. Statistical analysis included McNemar tests for binary outcomes and correlation analysis for multiclass comparisons with a significance threshold of P < .05. Physician satisfaction scores showed strong correlation between models with r-values of 0.665 and 0.558 and P-values below .001. Both models demonstrated high accuracy in data extraction and integration. The mean accuracy for primary lesion features was 91.7% for GPT-4% and 92.1% for DeepSeek, while feature synthesis accuracy was 93.4% for GPT4 and 93.9% for DeepSeek. Metastatic lesion identification showed comparable overall accuracy at 93.5% for GPT4 and 94.4% for DeepSeek. GPT-4 performed better in pleural lesion detection with 94.9% accuracy compared to 79.5% for DeepSeek, whereas DeepSeek achieved higher accuracy in mesenteric metastasis identification at 87.5% vs 43.8% for GPT4. TNM staging accuracy exceeded 92% for T-stage and 94% for M-stage, with N-stage accuracy improving beyond 90% when supplemented with physical exam data. Both GPT-4 and DeepSeek effectively generate structured breast cancer imaging reports with high accuracy in data mining, integration, and TNM staging. Integrating these models into clinical practice is expected to enhance report standardization and physician productivity.

Nasr M, Piórkowski A, Brzostowski K, El-Samie FEA

pubmed logopapersAug 7 2025
Denoising reconstructed Computed Tomography (CT) images without access to raw projection data remains a significant difficulty in medical imaging, particularly when utilizing sharp or medium reconstruction kernels that generate high-frequency noise. This work introduces an innovative method that integrates quaternion mathematics with bilateral filtering to resolve this issue. The proposed Quaternion Bilateral Filter (QBF) effectively maintains anatomical structures and mitigates noise caused by the kernel by expressing CT scans in quaternion form, with the red, green, and blue channels encoded together. Compared to conventional methods that depend on raw data or grayscale filtering, our approach functions directly on reconstructed sharp kernel images. It converts them to mimic the quality of soft-kernel outputs, obtained with kernels such as B30f, using paired data from the same patients. The efficacy of the QBF is evidenced by both full-reference metrics (Structural Similarity Index Measure (SSIM), Peak Signal-to-Noise Ratio (PSNR), Mean Absolute Error (MAE), and Root Mean Squared Error (RMSE)) and no-reference perceptual metrics (Naturalness Image Quality Evaluator (NIQE), Blind Referenceless Image Spatial Quality Evaluator (BRISQUE), and Perception-based Image Quality Evaluator (PIQE)). The results indicate that the QBF demonstrates improved denoising efficacy compared to traditional Bilateral Filter (BF), Non-Local Means (NLM), wavelet, and Convolutional Neural Network (CNN)-based processing, achieving an SSIM of 0.96 and a PSNR of 36.3 on B50f reconstructions. Additionally, segmentation-based visual validation verifies that QBF-filtered outputs maintain essential structural details necessary for subsequent diagnostic tasks. This study emphasizes the importance of quaternion-based filtering as a lightweight, interpretable, and efficient substitute for deep learning models in post-reconstruction CT image enhancement.

Fontaine J, Suszko M, di Franco F, Leroux A, Bonnet E, Bosset M, Langrand-Escure J, Clippe S, Fleury B, Guy JB

pubmed logopapersAug 7 2025
AI-based automatic contouring streamlines radiotherapy by reducing contouring time but requires rigorous validation and ongoing daily monitoring. This study assessed how software updates affect contouring accuracy and examined how image quality variations influence AI performance. Two patient cohorts were analyzed. The software updates cohort (40 CT scans: 20 thorax, 10 pelvis, 10 H&N) compared six versions of Limbus AI contouring software. The image quality cohort (20 patients: H&N, pelvis, brain, thorax) analyzed 12 reconstructions per patient using Standard, iDose, and IMR algorithms, with simulated noise and spatial resolution (SR) degradations. AI performance was assessed using Volumetric Dice Similarity Coefficient (vDSC) and 95 % Hausdorff Distance (HD95%) with Wilcoxon tests for significance. In the software updates cohort, vDSC improved for re-trained structures across versions (mean DSC ≥ 0.75), with breast contour vDSC decreasing by 1 % between v1.5 and v1.8B3 (p > 0.05). Median HD95% values were consistently <4 mm, <5 mm, and <12 mm for H&N, pelvis, and thorax contours, respectively (p > 0.05). In the image quality cohort, no significant differences were observed between Standard, iDose, and IMR algorithms. However, noise and SR degradation significantly reduced performance: vDSC ≥ 0.9 dropped from 89 % at 2 % noise to 30 % at 20 %, and from 87 % to 70 % as SR degradation increased (p < 0.001). AI contouring accuracy improved with software updates and showed robustness to minor reconstruction variations, but it was sensitive to noise and SR degradation. Continuous validation and quality control of AI-generated contours are essential. Future studies should include a broader range of anatomical regions and larger cohorts.
Page 291 of 6596585 results
Show
per page

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.