Sort by:
Page 39 of 1331328 results

Spatio-Temporal Conditional Diffusion Models for Forecasting Future Multiple Sclerosis Lesion Masks Conditioned on Treatments

Gian Mario Favero, Ge Ya Luo, Nima Fathi, Justin Szeto, Douglas L. Arnold, Brennan Nichyporuk, Chris Pal, Tal Arbel

arxiv logopreprintAug 9 2025
Image-based personalized medicine has the potential to transform healthcare, particularly for diseases that exhibit heterogeneous progression such as Multiple Sclerosis (MS). In this work, we introduce the first treatment-aware spatio-temporal diffusion model that is able to generate future masks demonstrating lesion evolution in MS. Our voxel-space approach incorporates multi-modal patient data, including MRI and treatment information, to forecast new and enlarging T2 (NET2) lesion masks at a future time point. Extensive experiments on a multi-centre dataset of 2131 patient 3D MRIs from randomized clinical trials for relapsing-remitting MS demonstrate that our generative model is able to accurately predict NET2 lesion masks for patients across six different treatments. Moreover, we demonstrate our model has the potential for real-world clinical applications through downstream tasks such as future lesion count and location estimation, binary lesion activity classification, and generating counterfactual future NET2 masks for several treatments with different efficacies. This work highlights the potential of causal, image-based generative models as powerful tools for advancing data-driven prognostics in MS.

SST-DUNet: Smart Swin Transformer and Dense UNet for automated preclinical fMRI skull stripping.

Soltanpour S, Utama R, Chang A, Nasseef MT, Madularu D, Kulkarni P, Ferris CF, Joslin C

pubmed logopapersAug 9 2025
Skull stripping is a common preprocessing step in Magnetic Resonance Imaging (MRI) pipelines and is often performed manually. Automating this process is challenging for preclinical data due to variations in brain geometry, resolution, and tissue contrast. Existing methods for MRI skull stripping often struggle with the low resolution and varying slice sizes found in preclinical functional MRI (fMRI) data. This study proposes a novel method that integrates a Dense UNet-based architecture with a feature extractor based on the Smart Swin Transformer (SST), called SST-DUNet. The Smart Shifted Window Multi-Head Self-Attention (SSW-MSA) module in SST replaces the mask-based module in the Swin Transformer (ST), enabling the learning of distinct channel-wise features while focusing on relevant dependencies within brain structures. This modification allows the model to better handle the complexities of fMRI skull stripping, such as low resolution and variable slice sizes. To address class imbalance in preclinical data, a combined loss function using Focal and Dice loss is applied. The model was trained on rat fMRI images and evaluated across three in-house datasets, achieving Dice similarity scores of 98.65%, 97.86%, and 98.04%. We compared our method with conventional and deep learning-based approaches, demonstrating its superiority over state-of-the-art methods. The fMRI results using SST-DUNet closely align with those from manual skull stripping for both seed-based and independent component analyses, indicating that SST-DUNet can effectively substitute manual brain extraction in rat fMRI analysis.

LWT-ARTERY-LABEL: A Lightweight Framework for Automated Coronary Artery Identification

Shisheng Zhang, Ramtin Gharleghi, Sonit Singh, Daniel Moses, Dona Adikari, Arcot Sowmya, Susann Beier

arxiv logopreprintAug 9 2025
Coronary artery disease (CAD) remains the leading cause of death globally, with computed tomography coronary angiography (CTCA) serving as a key diagnostic tool. However, coronary arterial analysis using CTCA, such as identifying artery-specific features from computational modelling, is labour-intensive and time-consuming. Automated anatomical labelling of coronary arteries offers a potential solution, yet the inherent anatomical variability of coronary trees presents a significant challenge. Traditional knowledge-based labelling methods fall short in leveraging data-driven insights, while recent deep-learning approaches often demand substantial computational resources and overlook critical clinical knowledge. To address these limitations, we propose a lightweight method that integrates anatomical knowledge with rule-based topology constraints for effective coronary artery labelling. Our approach achieves state-of-the-art performance on benchmark datasets, providing a promising alternative for automated coronary artery labelling.

OctreeNCA: Single-Pass 184 MP Segmentation on Consumer Hardware

Nick Lemke, John Kalkhof, Niklas Babendererde, Anirban Mukhopadhyay

arxiv logopreprintAug 9 2025
Medical applications demand segmentation of large inputs, like prostate MRIs, pathology slices, or videos of surgery. These inputs should ideally be inferred at once to provide the model with proper spatial or temporal context. When segmenting large inputs, the VRAM consumption of the GPU becomes the bottleneck. Architectures like UNets or Vision Transformers scale very poorly in VRAM consumption, resulting in patch- or frame-wise approaches that compromise global consistency and inference speed. The lightweight Neural Cellular Automaton (NCA) is a bio-inspired model that is by construction size-invariant. However, due to its local-only communication rules, it lacks global knowledge. We propose OctreeNCA by generalizing the neighborhood definition using an octree data structure. Our generalized neighborhood definition enables the efficient traversal of global knowledge. Since deep learning frameworks are mainly developed for large multi-layer networks, their implementation does not fully leverage the advantages of NCAs. We implement an NCA inference function in CUDA that further reduces VRAM demands and increases inference speed. Our OctreeNCA segments high-resolution images and videos quickly while occupying 90% less VRAM than a UNet during evaluation. This allows us to segment 184 Megapixel pathology slices or 1-minute surgical videos at once.

"AI tumor delineation for all breathing phases in early-stage NSCLC".

DelaO-Arevalo LR, Sijtsema NM, van Dijk LV, Langendijk JA, Wijsman R, van Ooijen PMA

pubmed logopapersAug 9 2025
Accurate delineation of the Gross Tumor Volume (GTV) and the Internal Target Volume (ITV) in early-stage lung tumors is crucial in Stereotactic Body Radiation Therapy (SBRT). Traditionally, the ITVs, which account for breathing motion, are generated by manually contouring GTVs across all breathing phases (BPs), a time-consuming process. This research aims to streamline this workflow by developing a deep learning algorithm to automatically delineate GTVs in all four-dimensional computed tomography (4D-CT) BPs for early-stage Non-Small Cell Lung Cancer Patients (NSCLC). A dataset of 214 early-stage NSCLC patients treated with SBRT was used. Each patient had a 4D-CT scan containing ten reconstructed BPs. The data were divided into a training set (75 %) and a testing set (25 %). Three models SwinUNetR and Dynamic UNet (DynUnet), and a hybrid model combining both (Swin + Dyn)were trained and evaluated using the Dice Similarity Coefficient (DSC), 3 mm Surface Dice Similarity Coefficient (SDSC), and the 95<sup>th</sup> percentile Hausdorff distance (HD95). The best performing model was used to delineate GTVs in all test set BPs, creating the ITVs using two methods: all 10 phases and the maximum inspiration/expiration phases. The ITVs were compared to the ground truth ITVs. The Swin + Dyn model achieved the highest performance, with a test set SDSC of 0.79 ± 0.14 for GTV 50 %. For the ITVs, the SDSC was 0.79 ± 0.16 using all 10 BPs and 0.77 ± 0.14 using 2 BPs. At the voxel level, the Swin + DynNet network achieved a sensitivity of 0.75 ± 0.14 and precision of 0.84 ± 0.10 for the ITV 2 breathing phases, and a sensitivity of 0.79 ± 0.12 and precision of 0.80 ± 0.11 for the 10 breathing phases. The Swin + Dyn Net algorithm, trained on the maximum expiration CT-scan effectively delineated gross tumor volumes in all breathing phases and the resulting ITV showed a good agreement with the ground truth (surface DSC = 0.79 ± 0.16 using all 10 BPs and 0.77 ± 0.14 using 2 BPs.). The proposed approach could reduce delineation time and inter-performer variability in the tumor contouring process for NSCLC SBRT workflows.

Kidney volume after endovascular exclusion of abdominal aortic aneurysms by EVAR and FEVAR.

B S, C V, Turkia J B, Weydevelt E V, R P, F L, A K

pubmed logopapersAug 9 2025
Decreased kidney volume is a sign of renal aging and/or decreased vascularization. The aim of this study was to determine whether renal volume changes 24 months after exclusion of an abdominal aortic aneurysm (AAA), and to compare fenestrated (FEVAR) and subrenal (EVAR) stents. Retrospective single-center study from a prospective registry, including patients between 60 and 80 years with normal preoperative renal function (eGFR≥60 ml/min/1.73 m<sup>-2</sup>) who underwent fenestrated (FEVAR) or infrarenal (EVAR) stent grafts between 2015 and 2021. Patients had to have had an CT scan at 24 months of the study to be included. Exclusion criteria were renal branches, the presence of preoperative renal insufficiency, a single kidney, embolization or coverage of an accessory renal artery, occlusion of a renal artery during follow-up and mention of AAA rupture. Renal volume was measured using sizing software (EndoSize, therenva) based on fully automatic deep-learning segmentation of several anatomical structures (arterial lumen, bone structure, thrombus, heart, etc.), including the kidneys. In the presence of renal cysts, these were manually excluded from the segmentation. Forty-eight patients were included (24 EVAR vs. 24 FEVAR), 96 kidneys were segmented. There was no difference between groups in age (78.9±6.7 years vs. 69.4±6.8, p=0.89), eGFR 85.8 ± 12.4 [62-107] ml/min/1.73 m<sup>-2</sup> vs. 81 ± 16.2 [42-107] (p=0.36), and renal volume 170.9 ± 29.7 [123-276] mL vs. 165.3 ± 37.4 [115-298] (p=0.12). At 24 months in the EVAR group, there was a non-significant reduction in eGFR 84.1 ± 17.2 [61-128] ml/min/1.73 m<sup>-2</sup> vs. 81 ± 16.2 [42-107] (p=0.36) or renal volume 170.9 ± 29.7 [123-276] mL vs. 165.3 ± 37.4 [115-298] (p=0.12). In the FEVAR group, at 24 months there was a non-significant fall in eGFR 84.1 ± 17.2 [61-128] ml/min/1.73 m<sup>-2</sup> vs. 73.8 ± 21.4 [40-110] (p=0.09), while renal volume decreased significantly 182 ± 37.8 [123-293] mL vs. 158.9 ± 40.2 [45-258] (p=0.007). In this study, there appears to be a significant decrease in renal volume without a drop in eGFR 24 months after fenestrated stenting. This decrease may reflect changes in renal perfusion and could potentially be predictive of long-term renal impairment, although this cannot be confirmed within the limits of this small sample. Further studies with long-term follow-up are needed.

Supporting intraoperative margin assessment using deep learning for automatic tumour segmentation in breast lumpectomy micro-PET-CT.

Maris L, Göker M, De Man K, Van den Broeck B, Van Hoecke S, Van de Vijver K, Vanhove C, Keereman V

pubmed logopapersAug 9 2025
Complete tumour removal is vital in curative breast cancer (BCa) surgery to prevent recurrence. Recently, [<sup>18</sup>F]FDG micro-PET-CT of lumpectomy specimens has shown promise for intraoperative margin assessment (IMA). To aid interpretation, we trained a 2D Residual U-Net to delineate invasive carcinoma of no special type in micro-PET-CT lumpectomy images. We collected 53 BCa lamella images from 19 patients with true histopathology-defined tumour segmentations. Group five-fold cross-validation yielded a dice similarity coefficient of 0.71 ± 0.20 for segmentation. Afterwards, an ensemble model was generated to segment tumours and predict margin status. Comparing predicted and true histopathological margin status in a separate set of 31 micro-PET-CT lumpectomy images of 31 patients achieved an F1 score of 84%, closely matching the mean performance of seven physicians who manually interpreted the same images. This model represents an important step towards a decision-support system that enhances micro-PET-CT-based IMA in BCa, facilitating its clinical adoption.

Self-supervised disc and cup segmentation via non-local deformable convolution and adaptive transformer.

Zhao W, Wang Y

pubmed logopapersAug 9 2025
Optic disc and cup segmentation is a crucial subfield of computer vision, playing a pivotal role in automated pathological image analysis. It enables precise, efficient, and automated diagnosis of ocular conditions, significantly aiding clinicians in real-world medical applications. However, due to the scarcity of medical segmentation data and the insufficient integration of global contextual information, the segmentation accuracy remains suboptimal. This issue becomes particularly pronounced in optic disc and cup cases with complex anatomical structures and ambiguous boundaries.In order to address these limitations, this paper introduces a self-supervised training strategy integrated with a newly designed network architecture to improve segmentation accuracy.Specifically,we initially propose a non-local dual deformable convolutional block,which aims to capture the irregular image patterns(i.e. boundary).Secondly,we modify the traditional vision transformer and design an adaptive K-Nearest Neighbors(KNN) transformation block to extract the global semantic context from images. Finally,an initialization strategy based on self-supervised training is proposed to reduce the burden on the network on labeled data.Comprehensive experimental evaluations demonstrate the effectiveness of our proposed method, which outperforms previous networks and achieves state-of-the-art performance,with IOU scores of 0.9577 for the optic disc and 0.8399 for the optic cup on the REFUGE dataset.

Stenosis degree and plaque burden differ between the major epicardial coronary arteries supplying ischemic territories.

Kero T, Knuuti J, Bär S, Bax JJ, Saraste A, Maaniitty T

pubmed logopapersAug 9 2025
It is unclear whether coronary artery stenosis, plaque burden, and composition differ between major epicardial arteries supplying ischemic myocardial territories. We studied 837 symptomatic patients undergoing coronary computed tomography angiography (CTA) and <sup>15</sup>O-water PET myocardial perfusion imaging for suspected obstructive coronary artery disease. Coronary CTA was analyzed using Artificial Intelligence-Guided Quantitative Computed Tomography (AI-QCT) to assess stenosis and atherosclerotic plaque characteristics. Myocardial ischemia was defined by regional PET perfusion in the left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) territories. Among arteries supplying ischemic territories, the LAD exhibited significantly higher stenosis and both absolute and normalized plaque volumes compared to LCX and RCA (p<0.001 for all). Multivariable logistic regression showed diameter stenosis (p=0.001-0.015), percent atheroma volume (PAV; p<0.001), and percent non-calcified plaque volume (p=0.001-0.017) were associated with ischemia across all three arteries. Percent calcified plaque volume was associated with ischemia only in the RCA (p=0.001). The degree of stenosis and atherosclerotic burden are significantly higher in LAD as compared to LCX and RCA, both in epicardial coronary arteries supplying non-ischemic or ischemic myocardial territories. In all the three main coronary arteries both luminal narrowing and plaque burden are independent predictors of ischemia, where the plaque burden is mainly driven by non-calcified plaque. However, many vessels supplying ischemic territories have relatively low stenosis degree and plaque burden, especially in the LCx and RCA, limiting the ability of diameter stenosis and PAV to predict myocardial ischemia.

Automated 3D segmentation of rotator cuff muscle and fat from longitudinal CT for shoulder arthroplasty evaluation.

Yang M, Jun BJ, Owings T, Subhas N, Polster J, Winalski CS, Ho JC, Entezari V, Derwin KA, Ricchetti ET, Li X

pubmed logopapersAug 9 2025
To develop and validate a deep learning model for automated 3D segmentation of rotator cuff muscles on longitudinal CT scans to quantify muscle volume and fat fraction in patients undergoing total shoulder arthroplasty (TSA). The proposed segmentation models adopted DeepLabV3 + with ResNet50 as the backbone. The models were trained, validated, and tested on preoperative or minimum 2-year follow-up CT scans from 53 TSA subjects. 3D Dice similarity scores, average symmetric surface distance (ASSD), 95th percentile Hausdorff distance (HD95), and relative absolute volume difference (RAVD) were used to evaluate the model performance on hold-out test sets. The trained models were applied to a cohort of 172 patients to quantify rotator cuff muscle volumes and fat fractions across preoperative and minimum 2- and 5-year follow-ups. Compared to the ground truth, the models achieved mean Dice of 0.928 and 0.916, mean ASSD of 0.844 mm and 1.028 mm, mean HD95 of 3.071 mm and 4.173 mm, and mean RAVD of 0.025 and 0.068 on the hold-out test sets for the pre-operative and the minimum 2-year follow-up CT scans, respectively. This study developed accurate and reliable deep learning models for automated 3D segmentation of rotator cuff muscles on clinical CT scans in TSA patients. These models substantially reduce the time required for muscle volume and fat fraction analysis and provide a practical tool for investigating how rotator cuff muscle health relates to surgical outcomes. This has the potential to inform patient selection, rehabilitation planning, and surgical decision-making in TSA and RCR.
Page 39 of 1331328 results
Show
per page

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.