Sort by:
Page 1 of 329 results
Next

Three-dimensional pulp chamber volume quantification in first molars using CBCT: Implications for machine learning-assisted age estimation

Ding, Y., Zhong, T., He, Y., Wang, W., Zhang, S., Zhang, X., Shi, W., jin, b.

medrxiv logopreprintAug 8 2025
Accurate adult age estimation represents a critical component of forensic individual identification. However, traditional methods relying on skeletal developmental characteristics are susceptible to preservation status and developmental variation. Teeth, owing to their exceptional taphonomic resistance and minimal postmortem alteration, emerge as premier biological samples. Utilizing the high-resolution capabilities of Cone Beam Computed Tomography (CBCT), this study retrospectively analyzed 1,857 right first molars obtained from Han Chinese adults in Sichuan Province (883 males, 974 females; aged 18-65 years). Pulp chamber volume (PCV) was measured using semi-automatic segmentation in Mimics software (v21.0). Statistically significant differences in PCV were observed based on sex and tooth position (maxillary vs. mandibular). Significant negative correlations existed between PCV and age (r = -0.86 to -0.81). The strongest correlation (r = -0.88) was identified in female maxillary first molars. Eleven curvilinear regression models and six machine learning models (Linear Regression, Lasso Regression, Neural Network, Random Forest, Gradient Boosting, and XGBoost) were developed. Among the curvilinear regression models, the cubic model demonstrated the best performance, with the female maxillary-specific model achieving a mean absolute error (MAE) of 4.95 years. Machine learning models demonstrated superior accuracy. Specifically, the sex- and tooth position-specific XGBoost model for female maxillary first molars achieved an MAE of 3.14 years (R{superscript 2} = 0.87). This represents a significant 36.5% reduction in error compared to the optimal cubic regression model. These findings demonstrate that PCV measurements in first molars, combined with machine learning algorithms (specifically XGBoost), effectively overcome the limitations of traditional methods, providing a highly precise and reproducible approach for forensic age estimation.

Equivariant Spatiotemporal Transformers with MDL-Guided Feature Selection for Malignancy Detection in Dynamic PET

Dadashkarimi, M.

medrxiv logopreprintAug 6 2025
Dynamic Positron Emission Tomography (PET) scans offer rich spatiotemporal data for detecting malignancies, but their high-dimensionality and noise pose significant challenges. We introduce a novel framework, the Equivariant Spatiotemporal Transformer with MDL-Guided Feature Selection (EST-MDL), which integrates group-theoretic symmetries, Kolmogorov complexity, and Minimum Description Length (MDL) principles. By enforcing spatial and temporal symmetries (e.g., translations and rotations) and leveraging MDL for robust feature selection, our model achieves improved generalization and interpretability. Evaluated on three realworld PET datasets--LUNG-PET, BRAIN-PET, and BREAST-PET--our approach achieves AUCs of 0.94, 0.92, and 0.95, respectively, outperforming CNNs, Vision Transformers (ViTs), and Graph Neural Networks (GNNs) in AUC, sensitivity, specificity, and computational efficiency. This framework offers a robust, interpretable solution for malignancy detection in clinical settings.

The Effectiveness of Large Language Models in Providing Automated Feedback in Medical Imaging Education: A Protocol for a Systematic Review

Al-Mashhadani, M., Ajaz, F., Guraya, S. S., Ennab, F.

medrxiv logopreprintAug 6 2025
BackgroundLarge Language Models (LLMs) represent an ever-emerging and rapidly evolving generative artificial intelligence (AI) modality with promising developments in the field of medical education. LLMs can provide automated feedback services to medical trainees (i.e. medical students, residents, fellows, etc.) and possibly serve a role in medical imaging education. AimThis systematic review aims to comprehensively explore the current applications and educational outcomes of LLMs in providing automated feedback on medical imaging reports. MethodsThis study employs a comprehensive systematic review strategy, involving an extensive search of the literature (Pubmed, Scopus, Embase, and Cochrane), data extraction, and synthesis of the data. ConclusionThis systematic review will highlight the best practices of LLM use in automated feedback of medical imaging reports and guide further development of these models.

CAPoxy: a feasibility study to investigate multispectral imaging in nailfold capillaroscopy

Taylor-Williams, M., Khalil, I., Manning, J., Dinsdale, G., Berks, M., Porcu, L., Wilkinson, S., Bohndiek, S., Murray, A.

medrxiv logopreprintAug 5 2025
BackgroundNailfold capillaroscopy enables visualisation of structural abnormalities in the microvasculature of patients with systemic sclerosis (SSc). The objective of this feasibility study was to determine whether multispectral imaging could provide functional assessment (differences in haemoglobin concentration or oxygenation) of capillaries to aid discrimination between healthy controls and patients with SSc. MSI of nailfold capillaries visualizes the smallest blood vessels and the impact of SSc on angiogenesis and their deformation, making it suitable for evaluating oxygenation-sensitive imaging techniques. Imaging of the nailfold capillaries offers tissue-specific oxygenation information, unlike pulse oximetry, which measures arterial blood oxygenation as a single-point measurement. MethodsThe CAPoxy study was a single-centre, cross-sectional, feasibility study of nailfold capillary multispectral imaging, comparing a cohort of patients with SSc to controls. A nine-band multispectral camera was used to image 22 individuals (10 patients with SSc and 12 controls). Linear mixed-effects models and summary statistics were used to compare the different regions of the nailfold (capillaries, surrounding edges, and outside area) between SSc and controls. A machine learning model was used to compare the two groups. ResultsPatients with SSc exhibited higher indicators of haemoglobin concentration in the capillary and adjacent regions compared to controls, which were significant in the regions surrounding the capillaries (p<0.001). There were also spectral differences between the SSc and controls groups that could indicate differences in oxygenation of the capillaries and surrounding tissue. Additionally, a machine learning model distinguished SSc patients from healthy controls with an accuracy of 84%, suggesting potential for multispectral imaging to classify SSc based on structural and functional microvascular changes. ConclusionsData indicates that multispectral imaging differentiates between patients with SSc from controls based on differences in vascular function. Further work to develop a targeted spectral camera would further improve the contrast between patients with SSc and controls, enabling better imaging. Key messagesMultispectral imaging holds promise for providing functional oxygenation measurement in nailfold capillaroscopy. Significant oxygenation differences between individuals with systemic sclerosis and healthy controls can be detected with multispectral imaging in the tissue surrounding capillaries.

Delineating retinal breaks in ultra-widefield fundus images with a PraNet-based machine learning model

Takayama, T., Uto, T., Tsuge, T., Kondo, Y., Tampo, H., Chiba, M., Kaburaki, T., Yanagi, Y., Takahashi, H.

medrxiv logopreprintAug 5 2025
BackgroundRetinal breaks are critical lesions that can lead to retinal detachment and vision loss if not detected and treated early. Automated and precise delineation of retinal breaks using ultra- widefield fundus (UWF) images remain a significant challenge in ophthalmology. ObjectiveThis study aimed to develop and validate a deep learning model based on the PraNet architecture for the accurate delineation of retinal breaks in UWF images, with a particular focus on segmentation performance in retinal break-positive cases. MethodsWe developed a deep learning segmentation model based on the PraNet architecture. This study utilized a dataset consisting of 8,083 cases and a total of 34,867 UWF images. Of these, 960 images contained retinal breaks, while the remaining 33,907 images did not. The dataset was split into 34,713 images for training, 81 for validation, and 73 for testing. The model was trained and validated on this dataset. Model performance was evaluated using both image-wise segmentation metrics (accuracy, precision, recall, Intersection over Union (IoU), dice score, centroid distance score) and lesion-wise detection metrics (sensitivity, positive predictive value). ResultsThe PraNet-based model achieved an accuracy of 0.996, a precision of 0.635, a recall of 0.756, an IoU of 0.539, a dice score of 0.652, and a centroid distance score of 0.081 for pixel-level detection of retinal breaks. The lesion-wise sensitivity was calculated as 0.885, and the positive predictive value (PPV) was 0.742. ConclusionsTo our knowledge, this is the first study to present pixel-level localization of retinal breaks using deep learning on UWF images. Our findings demonstrate that the PraNet-based model provides precise and robust pixel-level segmentation of retinal breaks in UWF images. This approach offers a clinically applicable tool for the precise delineation of retinal breaks, with the potential to improve patient outcomes. Future work should focus on external validation across multiple institutions and integration of additional annotation strategies to further enhance model performance and generalizability.

Automated Assessment of Choroidal Mass Dimensions Using Static and Dynamic Ultrasonographic Imaging

Emmert, N., Wall, G., Nabavi, A., Rahdar, A., Wilson, M., King, B., Cernichiaro-Espinosa, L., Yousefi, S.

medrxiv logopreprintAug 1 2025
PurposeTo develop and validate an artificial intelligence (AI)-based model that automatically measures choroidal mass dimensions on B{square}scan ophthalmic ultrasound still images and cine loops. DesignRetrospective diagnostic accuracy study with internal and external validation. ParticipantsThe dataset included 1,822 still images and 283 cine loops of choroidal masses for model development and testing. An additional 182 still images were used for external validation, and 302 control images with other diagnoses were included to assess specificity MethodsA deep convolutional neural network (CNN) based on the U-Net architecture was developed to automatically measure the apical height and basal diameter of choroidal masses on B-scan ultrasound. All still images were manually annotated by expert graders and reviewed by a senior ocular oncologist. Cine loops were analyzed frame by frame and the frame with the largest detected mass dimensions was selected for evaluation. Outcome MeasuresThe primary outcome was the models measurement accuracy, defined by the mean absolute error (MAE) in millimeters, compared to expert manual annotations, for both apical height and basal diameter. Secondary metrics included the Dice coefficient, coefficient of determination (R2), and mean pixel distance between predicted and reference measurements. ResultsOn the internal test set of still images, the model successfully detected the tumor in 99.7% of cases. The mean absolute error (MAE) was 0.38 {+/-} 0.55 mm for apical height (95.1% of measurements <1 mm of the expert annotation) and was 0.99 {+/-} 1.15 mm for basal diameter (64.4% of measurements <1 mm). Linear agreement between predicted and reference measurements was strong, with R2 values of 0.74 for apical height and 0.89 for basal diameter. When applied to the control set of 302 control images, the model demonstrated a moderate false positive rate. On the external validation set, the model maintained comparable accuracy. Among the cine loops, the model detected tumors in 89.4% of cases with comparable accuracy. ConclusionDeep learning can deliver fast, reproducible, millimeter{square}level measurements of choroidal mass dimensions with robust performance across different mass types and imaging sources. These findings support the potential clinical utility of AI-assisted measurement tools in ocular oncology workflows.

Deep learning aging marker from retinal images unveils sex-specific clinical and genetic signatures

Trofimova, O., Böttger, L., Bors, S., Pan, Y., Liefers, B., Beyeler, M. J., Presby, D. M., Bontempi, D., Hastings, J., Klaver, C. C. W., Bergmann, S.

medrxiv logopreprintJul 29 2025
Retinal fundus images offer a non-invasive window into systemic aging. Here, we fine-tuned a foundation model (RETFound) to predict chronological age from color fundus images in 71,343 participants from the UK Biobank, achieving a mean absolute error of 2.85 years. The resulting retinal age gap (RAG), i.e., the difference between predicted and chronological age, was associated with cardiometabolic traits, inflammation, cognitive performance, mortality, dementia, cancer, and incident cardiovascular disease. Genome-wide analyses identified genes related to longevity, metabolism, neurodegeneration, and age-related eye diseases. Sex-stratified models revealed consistent performance but divergent biological signatures: males had younger-appearing retinas and stronger links to metabolic syndrome, while in females, both model attention and genetic associations pointed to a greater involvement of retinal vasculature. Our study positions retinal aging as a biologically meaningful and sex-sensitive biomarker that can support more personalized approaches to risk assessment and aging-related healthcare.

The impacts of artificial intelligence on the workload of diagnostic radiology services: A rapid review and stakeholder contextualisation

Sutton, C., Prowse, J., Elshehaly, M., Randell, R.

medrxiv logopreprintJul 24 2025
BackgroundAdvancements in imaging technology, alongside increasing longevity and co-morbidities, have led to heightened demand for diagnostic radiology services. However, there is a shortfall in radiology and radiography staff to acquire, read and report on such imaging examinations. Artificial intelligence (AI) has been identified, notably by AI developers, as a potential solution to impact positively the workload of radiology services for diagnostics to address this staffing shortfall. MethodsA rapid review complemented with data from interviews with UK radiology service stakeholders was undertaken. ArXiv, Cochrane Library, Embase, Medline and Scopus databases were searched for publications in English published between 2007 and 2022. Following screening 110 full texts were included. Interviews with 15 radiology service managers, clinicians and academics were carried out between May and September 2022. ResultsMost literature was published in 2021 and 2022 with a distinct focus on AI for diagnostics of lung and chest disease (n = 25) notably COVID-19 and respiratory system cancers, closely followed by AI for breast screening (n = 23). AI contribution to streamline the workload of radiology services was categorised as autonomous, augmentative and assistive contributions. However, percentage estimates, of workload reduction, varied considerably with the most significant reduction identified in national screening programmes. AI was also recognised as aiding radiology services through providing second opinion, assisting in prioritisation of images for reading and improved quantification in diagnostics. Stakeholders saw AI as having the potential to remove some of the laborious work and contribute service resilience. ConclusionsThis review has shown there is limited data on real-world experiences from radiology services for the implementation of AI in clinical production. Autonomous, augmentative and assistive AI can, as noted in the article, decrease workload and aid reading and reporting, however the governance surrounding these advancements lags.

SLOTMFound: Foundation-Based Diagnosis of Multiple Sclerosis Using Retinal SLO Imaging and OCT Thickness-maps

Esmailizadeh, R., Aghababaei, A., Mirzaei, S., Arian, R., Kafieh, R.

medrxiv logopreprintJul 15 2025
Multiple Sclerosis (MS) is a chronic autoimmune disorder of the central nervous system that can lead to significant neurological disability. Retinal imaging--particularly Scanning Laser Ophthalmoscopy (SLO) and Optical Coherence Tomography (OCT)--provides valuable biomarkers for early MS diagnosis through non-invasive visualization of neurodegenerative changes. This study proposes a foundation-based bi-modal classification framework that integrates SLO images and OCT-derived retinal thickness maps for MS diagnosis. To facilitate this, we introduce two modality-specific foundation models--SLOFound and TMFound--fine-tuned from the RETFound-Fundus backbone using an independent dataset of 203 healthy eyes, acquired at Noor Ophthalmology Hospital with the Heidelberg Spectralis HRA+OCT system. This dataset, which contains only normal cases, was used exclusively for encoder adaptation and is entirely disjoint from the classification dataset. For the classification stage, we use a separate dataset comprising IR-SLO images from 32 MS patients and 70 healthy controls, collected at the Kashani Comprehensive MS Center in Isfahan, Iran. We first assess OCT-derived maps layer-wise and identify the Ganglion Cell-Inner Plexiform Layer (GCIPL) as the most informative for MS detection. All subsequent analyses utilize GCIPL thickness maps in conjunction with SLO images. Experimental evaluations on the MS classification dataset demonstrate that our foundation-based bi-modal model outperforms unimodal variants and a prior ResNet-based state-of-the-art model, achieving a classification accuracy of 97.37%, with perfect sensitivity (100%). These results highlight the effectiveness of leveraging pre-trained foundation models, even when fine-tuned on limited data, to build robust, efficient, and generalizable diagnostic tools for MS in medical imaging contexts where labeled datasets are often scarce.

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based multi-modal X-ray microscope

Esposito, M., Astolfo, A., Zhou, Y., Buchanan, I., Teplov, A., Endrizzi, M., Egido Vinogradova, A., Makarova, O., Divan, R., Tang, C.-M., Yagi, Y., Lee, P. D., Walsh, C. L., Ferrara, J. D., Olivo, A.

medrxiv logopreprintJul 14 2025
With increasing interest in studying biological systems across spatial scales--from centimetres down to nanometres--histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterisation of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual H&E staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.
Page 1 of 329 results
Show
per page

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.