Abstract

BackgroundSegmentation of the left ventricular myocardium, left ventricular cavity, and right ventricular cavity on short-axis cine cardiac magnetic resonance (CMR) images is essential for quantifying cardiac structure and function. However, existing automated segmentation tools are limited by small training datasets, narrow disease coverage, restrictive input format requirements, and the absence of anatomical plausibility constraints, hindering their clinical adoption. MethodsWe constructed the largest annotated CMR short-axis segmentation dataset to date, comprising 1,555 subjects from 12 centers with five cardiac disease types and full cardiac cycle annotations totaling 319,175 labeled images. A MedNeXt-L model was trained using a 2D slice-by-slice strategy with full field-of-view input, eliminating dependencies on 3D volumes, temporal sequences, or region-of-interest(ROI) localization. A deterministic three-step post-processing pipeline was designed to enforce anatomical priors: connected component constraint, containment relationship constraint, and gap-filling constraint. The model was validated on an internal test set (310 subjects) and three independent public external datasets (ACDC, M&Ms1, M&Ms2; 855 subjects from 6 additional centers across 3 countries), spanning 15 cardiac disease categories--10 of which were never encountered during training. ResultsThe model achieved mean Dice similarity coefficients (DSC) of 0.913 {+/-} 0.037 and 0.911 {+/-} 0.040 on internal and external test sets, respectively, with a cross-domain performance gap of only 0.002. Post-processing eliminated all containment violations (7.5% [->] 0%) and gap errors (1.8% [->] 0%) while reducing fragment rates by 85.5% (9.0% [->] 1.3%). Zero-shot generalization to 10 unseen disease categories yielded DSC values ranging from 0.899 to 0.921. Automated clinical functional parameters demonstrated excellent agreement with manual measurements for left ventricular indices and right ventricular volumes (intraclass correlation coefficients [≥] 0.977). ConclusionsCorSeg-CineSAX provides a robust, open-source framework for fully automatic CMR short-axis segmentation across diverse clinical scenarios. All source code and pre-trained weights are publicly available at https://github.com/RunhaoXu2003/CorSeg.

Topics

cardiovascular medicine

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.