Back to all papers

Automatic diagnosis of osteonecrosis of the femoral head and segmentation of necrotic regions using deep learning at computed tomography: a real-world multicenter study.

June 25, 2026pubmed logopapers

Authors

Chen H,Zhou Y,Gao S,Liu C,Xi H,Gu C,Liu S,Xue P,Zhang C,Chen Y,Sun G,Liu X

Affiliations (7)

  • Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, 210029, China.
  • School of Electronics and Information Engineering, Soochow University, Suzhou, Jiangsu, 215006, China.
  • Nanjing Hospital of Chinese Medicine, Nanjing, Jiangsu, 210022, China.
  • The Second Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, 210022, China.
  • Nanchang Hongdu Hospital of Traditional Chinese Medicine, Nanchang, Jiangxi, 330006, China.
  • Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, 210029, China. [email protected].
  • Affiliated Hospital of Nanjing University of Chinese Medicine, Nanjing, Jiangsu, 210029, China. [email protected].

Abstract

Computed tomography (CT) is essential for diagnosing osteonecrosis of the femoral head (ONFH) due to its superior visualization of osseous structures, yet CT-based deep learning (DL) models remain underexplored in real-world settings. This retrospective multicenter study developed a two-stage DL model integrating Vision Transformer (ViT) and Swin Transformer (SwinT) for ONFH diagnosis and necrotic segmentation, using coronal CT images from 2,312 patients (53,828 images) across four hospitals from February 2023 to June 2024. The data from three hospitals were split 7:1:2 for training, validation, and internal testing, with the fourth serving as the external test set. Diagnostic performance was evaluated at both the slice and patient levels using the area under the receiver operating characteristic curve (AUC), sensitivity, and negative predictive value (NPV) while segmentation performance was assessed using the Dice coefficient and HD95. Human-computer comparison trials were conducted against three orthopaedic surgeons. At the slice level, the model achieved robust performance with strong results in internal test set (AUC = 0.98, sensitivity = 98.91%, NPV = 98.66%, Dice = 72.64%, HD95 = 4.51 mm) and external test set (AUC = 0.97, sensitivity = 99.61%, NPV = 99.63%, Dice = 69.11%, HD95 = 5.27 mm). At the patient level, diagnostic performance remained high, with AUCs of 0.98 and 0.97 in the internal and external test sets, respectively. It outperformed surgeons in diagnosis and matched a 10-year-experienced attending in segmentation. Our CT-based two-stage DL model exhibits high accuracy and strong generalizability for ONFH diagnosis and necrotic segmentation, providing a technically robust foundational framework with promising clinical translational potential for ONFH management. This study was registered in the Chinese Clinical Trial Registry chictr.org.cn (Registration ID: ChiCTR2300067945, 01/02/2023).

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.