Back to all papers

Precision, Prognosis and Clinical Performance of Rounded and Trabecular Segmentation of Cine CMR.

November 25, 2025pubmed logopapers

Authors

Joy G,Moon JC,Punjabi K,Alzahir M,Artico J,Shiwani H,Pierce I,Bhuva A,Thakur D,Xue H,Kellman P,Schelbert E,Treibel TA,Manisty C,Davies RH

Affiliations (8)

  • Institute of cardiovascular sciences, University College London, UK; Barts Heart Centre, St Bartholomew's Hospital, London, UK; Cardiovascular Clinical and Academic Group, City St George's University of London, UK.
  • Institute of cardiovascular sciences, University College London, UK; Barts Heart Centre, St Bartholomew's Hospital, London, UK.
  • Barts Heart Centre, St Bartholomew's Hospital, London, UK.
  • Institute of cardiovascular sciences, University College London, UK.
  • Health Futures, Microsoft Research, Redmond, Washington, USA.
  • National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Allina Health Minneapolis Heart Institute at United Hospital, Saint Paul, USA; University of Pittsburgh Medical Centre, USA.
  • Institute of cardiovascular sciences, University College London, UK; Barts Heart Centre, St Bartholomew's Hospital, London, UK. Electronic address: [email protected].

Abstract

Measurements of cardiac size and function drive clinical decisions. Left ventricle (LV) metrics can be derived from cardiac MR images by delineating the blood pool and myocardium, by either drawing a rounded contour to approximate the compacted myocardial border, or by delineating the papillary muscles and trabeculae (trabecular segmentation). There is no consensus as to which is best, particularly in the emergent AI era. We developed machine-learning (ML) approaches for both and compared them for clinically important metrics (error rate, precision, and prognosis). Separate ML models were developed for rounded and trabecular segmentation, using U-net models trained on 1,923 subjects (mixed pathology, multiple scanners, multiple centres). Blood and myocardial volumes for each segmentation method were compared on 4,118 healthy UK biobank subjects. Model segmentation quality was evaluated subjectively on a real-world clinical dataset of 1,594 consecutive CMR scans, with all scans included regardless of image quality and artefacts. Scan-rescan precision was measured on a multi-centre, multi-disease dataset of 109 subjects scanned twice and compared to human performance. Finally, prognostication ability was evaluated on 1,215 clinical patients, using a primary outcome of all-cause mortality and hospitalisation with heart failure. Error rates (where a human disagreed by >1ml) were the same, occurring in 0.6% of images and 3.6% (1 in 28) of patients. In health, the mean EF was 4% higher for trabecular vs rounded segmentation. On test-retest data, there was no difference between rounded and trabecular ML models for precision, apart from end-diastolic and end systolic volume, which was better for rounded segmentations. ML rounded and trabecular precision exceeded clinician performance for EF. There were marginal differences in prognostication between rounded and trabecular models. We developed an automated method for annotating papillary muscles and trabeculae from cardiac MR images with low error rates. We found higher precision than clinicians in ejection fraction. There was similar precision and prognostication to an ML rounded model with similarly low error rates. Findings support the feasibility of automated trabecular segmentation in clinical care and clinical trials.

Topics

Journal Article

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.