Assessment of T2-weighted MRI-derived synthetic CT for the detection of suspected lumbar facet arthritis: a comparative analysis with conventional CT.

Authors

Cao G,Wang H,Xie S,Cai D,Guo J,Zhu J,Ye K,Wang Y,Xia J

Affiliations (7)

  • Department of Radiology, Longgang Central Hospital of Shenzhen, Shenzhen, China.
  • Smart Medical Imaging, Learning and Engineering (SMILE) Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China.
  • Department of Radiology, The First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China.
  • Shenzhen Hospital of Guangzhou University of Chinese Medicine (Futian), Shenzhen, China.
  • Fuyong People's Hospital, Shenzhen, China.
  • Smart Medical Imaging, Learning and Engineering (SMILE) Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China. [email protected].
  • Department of Radiology, The First Affiliated Hospital of Shenzhen University, Health Science Center, Shenzhen Second People's Hospital, Shenzhen, China. [email protected].

Abstract

We evaluated sCT generated from T2-weighted imaging (T2WI) using deep learning techniques to detect structural lesions in lumbar facet arthritis, with conventional CT as the reference standard. This single-center retrospective study included 40 patients who had lumbar MRI and CT with in 1 week (September 2020 to August 2021). A Pix2Pix-GAN framework generated CT images from MRI data, and image quality was assessed using structural similarity index (SSIM), mean absolute error (MAE), peak signal-to-noise ratio (PSNR), nd Dice similarity coefficient (DSC). Two senior radiologists evaluated 15 anatomical landmarks. Sensitivity, specificity, and accuracy for detecting bone erosion, osteosclerosis, and joint space alterations were analyzed for sCT, T2-weighted MRI, and conventional CT. Forty participants (21 men, 19 women) were enrolled, with a mean age of 39 ± 16.9 years. sCT showed strong agreement with conventional CT, with SSIM values of 0.888 for axial and 0.889 for sagittal views. PSNR and MAE values were 24.56 dB and 0.031 for axial and 23.75 dB and 0.038 for sagittal views, respectively. DSC values were 0.935 for axial and 0.876 for sagittal views. sCT showed excellent intra- and inter-reader reliability intraclass correlation coefficients (0.953-0.995 and 0.839-0.983, respectively). sCT had higher sensitivity (57.9% vs. 5.3%), specificity (98.8% vs. 84.6%), and accuracy (93.0% vs. 73.3%) for bone erosion than T2-weighted MRI and outperformed it for osteosclerosis and joint space changes. sCT outperformed conventional T2-weighted MRI in detecting structural lesions indicative of lumbar facet arthritis, with conventional CT as the reference standard.

Topics

Journal Article

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.