Back to all papers

3D-ViT-UNet: 3D Vision transformer based Unet-like model for Volumetric Brain Tumor Segmentation.

March 31, 2026pubmed logopapers

Authors

Afridi S,Jan A,Irfan MA,Khattak MI,Khan TA

Affiliations (2)

  • Department of Electrical Engineering, University of Engineering and Technology, Peshawar, Pakistan.
  • School of Computer Science, Technological University Dublin (TU Dublin), Dublin, Ireland.

Abstract

Accurate volumetric segmentation of 3D medical imaging modalities is critical for therapy planning and clinical diagnosis, particularly for brain tumor delineation. Traditional convolutional neural network (CNN)-based architectures face challenges while capturing global contextual information and modeling long-range dependencies in complex 3D volumetric data, limiting their segmentation performance. Transformer-based models have emerged as promising alternatives to CNNs for such tasks, addressing their limitations in capturing global spatial dependencies. We propose 3D-ViT-UNet, a novel U-shaped vision transformer (ViT)-based encoder-decoder architecture for end-to-end volumetric brain tumor segmentation. The model employs 3D Window Multi-Head Self-Attention (3D-W-MSA) to capture local features and a 3D Dilated-Window Multi-Head Self-Attention (3D-DW-MSA) to capture global features while reducing computational complexity. Moreover, for preserving absolute and relative positional information and preventing permutation equivalence limitation in transformers, a dynamic position encoding strategy is integrated. The proposed model demonstrates state-of-the-art (SOTA) performance for brain tumor segmentation on the BraTS 2020 dataset. It achieves a superior average Dice Similarity Coefficient (DSC) of 84.81% and a Hausdorff Distance (HD) of 4.87 mm with reduced computational complexity compared to existing methods. Also, an improvement in delineation of tumor boundaries and accurate segmentation across modalities is demonstrated through the qualitative results. Extensive quantitative and qualitative evaluations highlight the capability of 3D-ViT-UNet to achieve high accuracy with a smaller model size and lower FLOPs, making it an effective and efficient solution for clinical applications involving volumetric brain tumor segmentation.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.