Prospective study assessing the validity of accelerated 2D Fast Spin Echo (2D FSE) based high-resolution knee MRI and T2 mapping using deep learning reconstruction.
Authors
Affiliations (4)
Affiliations (4)
- Department of Radiology, Renmin Hospital of Wuhan University, Wuhan, 430060, China.
- MR Research, GE Healthcare, Beijing, 100176, China.
- School of Computer Science, Wuhan University, Wuhan , China.
- Department of Radiology, Renmin Hospital of Wuhan University, Wuhan, 430060, China. [email protected].
Abstract
A routine fast spin-echo (FSE) MRI protocol is widely used to evaluate structural injuries of the knee. While adding a T2 mapping sequence to this protocol increases sensitivity for detecting early cartilage lesions, it is time-consuming. Deep learning reconstruction (DLR) can provide accelerated, high-quality imaging but requires further clinical validation. This study aimed to evaluate the image quality and diagnostic performance of an accelerated, high-resolution 2D FSE protocol using DLR. Additionally, it sought to determine whether a routine MR imaging protocol combining an accelerated T2 mapping sequence with DLR could improve diagnostic performance for the detection of cartilage lesions, using arthroscopy as the reference standard. A total of 92 patients underwent 2D FSE based routine knee imaging on 3.0T MRI, 39 of whom also underwent sagittal T2 mapping with different k-space-based acceleration factor of 2 or 3 and then reconstructed using conventional and deep learning reconstruction algorithms as FSE<sub>O</sub>, FSE<sub>DLR</sub>, T2<sub>O - ARC=2,3</sub>, and T2<sub>DLR - ARC=2,3</sub> and arthroscopy of the knee joint. Two radiologists subjectively and objectively evaluated both FSE<sub>O</sub> and FSE<sub>DLR</sub>. The inter-reader agreement for each pathology and image quality score was assessed using Cohen's κ. The objective metrics (SNR/CNR) between sequences was analyzed using paired t-test or Wilcoxon signed-rank test according to data normality. A two-sided p-value of less than 0.05 was considered statistically significant. Additionally, diagnostic performance of routine knee MR images and DLR or non-DLR T2 measurements respectively for grading knee cartilage were also compared. Articular cartilage was categorized according to International Cartilage Repair Society (ICRS). Each articular surface was then evaluated at arthroscopy. Receiver operating characteristic curve (ROC) was used to analyze diagnostic performance using arthroscopic results as reference. Inter-reader agreement of subjective assessment ranged from 0.70 (95% CI: 0.46-0.94,) to 0.89 (95% CI: 0.79-0.99,) and higher score on FSE<sub>DLR</sub> than FSE<sub>O</sub>. Sharpness for FSE<sub>DLR</sub> was rated to be excellent (median Likert score, 5; range, 5-5), higher compared to FSE<sub>O</sub> (median Likert score, 5; range,4-5),(P < 0.001)). Both SNR and CNR of FSE<sub>DLR</sub> were higher than those of FSE<sub>O</sub> (P < 0.001). Inter-reader agreement was almost perfect, withκvalues between 0.94 (95% CI: 0.85-1.0) to 1.00 (95% CI: 1.0-1.0) for the detection of internal derangement and substantial to almost perfect between 0.70 (95% CI:0.52-0.88) and 0.93 (95% CI:0.85-1.0) for the assessment of cartilage defects. FSE<sub>DLR</sub> (Reader 1 AUC, 0.77; 95% CI: 0.69-0.84 and Reader 2 AUC, 0.86; 95% CI: 0.78-0.91) had higher diagnostic performance than FSE<sub>O</sub> (Reader 1 AUC, 0.74; 95% CI: 0.66-0.81 and Reader 2 AUC, 0.80; 95% CI: 0.72-0.86; P = 0.005) for articular cartilage lesions. Moreover, Reader 1 achieved the higher diagnostic efficacy (AUC, 0.84; 95% CI: 0.76-0.90) in differentiating normal-appearing from injury-visible cartilage when using both routine FSE<sub>DLR</sub> images and T2<sub>DLR - ARC=2,</sub>while Reader 2 achieved an AUC of 0.86 (95% CI: 0.78-0.91) with routine FSE<sub>DLR</sub> images. Our preliminary results indicate that the accelerated DLR FSE protocol provided diagnostic performance equivalent to the standard protocol for internal derangement, with potential improvement for the detection of cartilage lesions, while delivering higher image quality and quantitative T2 data within a clinically feasible scan time. These findings suggest its potential value for a comprehensive and efficient assessment of knee injury.