Enhancing Synthetic Pelvic CT Generation from CBCT using Vision Transformer with Adaptive Fourier Neural Operators.

Authors

Bhaskara R,Oderinde OM

Affiliations (1)

  • School of Health Sciences, Purdue University College of Health and Human Sciences, 610 Purdue Mall, West Lafayette, Indiana, 47907-2060, UNITED STATES.

Abstract

This study introduces a novel approach to improve Cone Beam CT (CBCT) image quality by developing a synthetic CT (sCT) generation method using CycleGAN with a Vision Transformer (ViT) and an Adaptive Fourier Neural Operator (AFNO). 

Approach: A dataset of 20 prostate cancer patients who received stereotactic body radiation therapy (SBRT) was used, consisting of paired CBCT and planning CT (pCT) images. The dataset was preprocessed by registering pCTs to CBCTs using deformation registration techniques, such as B-spline, followed by resampling to uniform voxel sizes and normalization. The model architecture integrates a CycleGAN with bidirectional generators, where the UNet generator is enhanced with a ViT at the bottleneck. AFNO functions as the attention mechanism for the ViT, operating on the input data in the Fourier domain. AFNO's innovations handle varying resolutions, mesh invariance, and efficient long-range dependency capture.

Main Results: Our model improved significantly in preserving anatomical details and capturing complex image dependencies. The AFNO mechanism processed global image information effectively, adapting to interpatient variations for accurate sCT generation. Evaluation metrics like Mean Absolute Error (MAE), Peak Signal to Noise Ratio (PSNR), Structural Similarity Index (SSIM), and Normalized Cross Correlation (NCC), demonstrated the superiority of our method. Specifically, the model achieved an MAE of 9.71, PSNR of 37.08 dB, SSIM of 0.97, and NCC of 0.99, confirming its efficacy. 

Significance: The integration of AFNO within the CycleGAN UNet framework addresses Cone Beam CT image quality limitations. The model generates synthetic CTs that allow adaptive treatment planning during SBRT, enabling adjustments to the dose based on tumor response, thus reducing radiotoxicity from increased doses. This method's ability to preserve both global and local anatomical features shows potential for improving tumor targeting, adaptive radiotherapy planning, and clinical decision-making.

Topics

Journal Article

Ready to Sharpen Your Edge?