Automated breast ultrasound features associated with diagnostic performance of Multiview convolutional neural network according to radiologists' experience.
Authors
Affiliations (5)
Affiliations (5)
- Department of Radiology, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonbuk National University Medical School, Jeonju, Korea (the Republic of).
- Department of Electrical and Computer Engineering, University of Saskatchewan, Saskatoon, Canada.
- Department of Statistics, Jeonbuk National University, Research Institute of Applied Statistics, Jeonju City, Korea (the Republic of).
- Department of Radiology, Yonsei University College of Medicine, seoul, Korea (the Republic of).
- Research Institute of Radiology, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan, Korea (the Republic of).
Abstract
To investigate automated breast ultrasound (ABUS) features affecting the use of Multiview convolutional neural network (CNN) for breast lesions according to radiologists' experience. A total of 656 breast lesions (152 malignant and 504 benign lesions) were included and reviewed by six radiologists for background echotexture, glandular tissue component (GTC), and lesion type and size without as well as with Multiview CNN. The sensitivity, specificity, and the area under the receiver operating curve (AUC) for ABUS features were compared between two sessions according to radiologists' experience. Radiology residents showed significant AUC improvement with the Multiview CNN for mass (0.81 to 0.91, P=0.003) and non-mass lesions (0.56 to 0.90, P=0.007), all background echotextures (homogeneous-fat: 0.84 to 0.94, P=0.04; homogeneous-fibroglandular: 0.85 to 0.93, P=0.01; heterogeneous: 0.68 to 0.88, P=0.002), all GTC levels (minimal: 0.86 to 0.93, P=0.001; mild: 0.82 to 0.94, P=0.003; moderate: 0.75 to 0.88, P=0.01; marked: 0.68 to 0.89, P<0.001), and lesions ≤10mm (≤5 mm: 0.69 to 0.86, P<0.001; 6-10 mm: 0.83 to 0.92, P<0.001). Breast specialists showed significant AUC improvement with the Multiview CNN in heterogeneous echotexture (0.90 to 0.95, P=0.03), marked GTC (0.88 to 0.95, P<0.001), and lesions ≤10mm (≤5 mm: 0.89 to 0.93, P=0.02; 6-10 mm: 0.95 to 0.98, P=0.01). With the Multiview CNN, the performance of ABUS in radiology residents was improved regardless of lesion type, background echotexture, or GTC. For breast lesions smaller than 10 mm, both radiology residents and breast specialists showed better performance of ABUS.