Back to all papers

Total-body [<sup>18</sup>F]FDG-PET/CT imaging of healthy volunteers with minimal effective dose.

November 18, 2025pubmed logopapers

Authors

Ferrara D,Gutschmayer S,Chalampalakis Z,Geist BK,Özer Ö,Pires M,Rausch I,Langsteger W,Beyer T

Affiliations (3)

  • QIMP Team, Medical University of Vienna, Vienna, Austria.
  • QIMP Team, Medical University of Vienna, Vienna, Austria. [email protected].
  • Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria.

Abstract

High-sensitivity, total-body (TB) positron emission tomography (PET) and computed tomography (CT) imaging systems enable substantial reduction of injected radioactivity without compromising image quality. Synthetic CT-like attenuation maps can be generated from PET data via deep learning (DL) to further minimise subject radiation exposure. We explored combining TB-PET with DL-derived attenuation maps to minimise effective dose in healthy subjects undergoing TB-PET/CT imaging with [<sup>18</sup>F]Fluorodeoxyglucose ([<sup>18</sup>F]FDG). 47 healthy Caucasians (25 F/22 M, BMI: 24 ± 3 kg/m²) underwent TB-PET/CT imaging. After 6-hour fasting, subjects received low-dose CT (1 mSv) and (109 ± 7) MBq [<sup>18</sup>F]FDG, followed by a 62-minute dynamic PET acquisition (supine, arms down). PET data from 57 to 62 min were down-sampled to simulate reduced activities (50%, 25%, 10%, 5%). Effective doses (ED) were estimated for each activity level. Synthetic CTs (ED = 0 mSv) were generated from PET raw data (at all activity levels) and used to reconstruct attenuation-corrected PETs, which were compared to the original images. Organ-level segmentation enabled quantification of Standardized Uptake Values normalised to body weight (SUVbw) and coefficients of variation (CV). Across the cohort, organ-based SUVbw differences remained < 10% versus reference PET for simulated activities down to 10%. At 25% activity (~ 25 MBq, ED~ 0.45 mSv), PET quantification remained robust, though CV increased in skeletal muscle and fat. At 5% activity, SUVbw deviations exceeded 10% in several organs. Total-body [<sup>18</sup>F]FDG-PET/CT enables reliable organ-level quantification (%-differences < 10%) at injected activities as low as ~ 25 MBq. Such low-dose protocols may support the creation of reference datasets of healthy controls while minimising radiation exposure to subjects and staff.

Topics

Journal Article

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.