Back to all papers

Reference charts for first-trimester placental three-dimensional fractional moving blood volume derived using OxNNet.

January 7, 2026pubmed logopapers

Authors

Mathewlynn S,Starck LN,Yin Y,Soltaninejad M,Swinburne M,Nicolaides KH,Syngelaki A,Contreras AG,Bigiotti S,Woess EM,Gerry S,Collins S

Affiliations (6)

  • Nuffield Department of Women's and Reproductive Health, University of Oxford, Oxford, UK.
  • Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Fetal Medicine Research Institute, King's College Hospital, London, UK.
  • University of Bristol, Bristol, UK.
  • Centre for Statistics in Medicine, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK.
  • Birmingham Women and Children's NHS Foundation Trust, Birmingham, UK.

Abstract

To establish a comprehensive reference range for first-trimester placental three-dimensional (3D) single-vessel fractional moving blood volume (svFMBV) using the OxNNet toolkit, based on values observed in healthy pregnancies. This study utilized data from the First-trimester Placental Ultrasound (FirstPLUS) study, a longitudinal observational cohort study conducted between March and November 2022 at King's College Hospital, London, UK. Participants underwent 3D ultrasound assessment of the placenta, including power Doppler imaging, during routine first-trimester screening. The OxNNet toolkit was used for automated placental segmentation and 3D-svFMBV calculation. Quality control was performed in three stages to ensure image completeness and segmentation accuracy. Quantile regression and lambda-mu-sigma (LMS) modeling were used to construct reference charts for 3D-svFMBV. Model fit was assessed using the Akaike information criterion, and centile curves were constructed. The final cohort comprised 2547 cases. Visual assessment of histograms and quantile-quantile plots revealed positive skew in 3D-svFMBV determined at five specific locations within the uteroplacental vasculature. LMS modeling provided the best fit for constructing centile charts, with the Box-Cox Power Exponential original distribution used in most cases. The resulting centile charts demonstrated close agreement between predicted and observed centiles, with minimal deviation across all target centiles. This study provides novel reference ranges for first-trimester placental 3D-svFMBV at five locations within the uteroplacental vasculature. These findings offer a valuable foundation for future research into placental function and pregnancy outcome. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 8,000+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.