Quantitative Real-Time MRI for the Assessment of Gastric Motility.
Authors
Affiliations (7)
Affiliations (7)
- Department of Biopharmaceutics and Pharmaceutical Technology, Institute of Pharmacy, University of Greifswald, Greifswald, Germany.
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen, Germany.
- Department of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.
- Department of Internal Medicine A, University Medicine Greifswald, Greifswald, Germany.
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, UK.
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
- Department of Medical Physics, University of Greifswald, Institute of Physics, Greifswald, Germany.
Abstract
Current reference standards for measuring gastric emptying and motility are not considered optimal due to the time required, ionizing radiation, invasiveness, and spatial resolution. To assess gastric motility using novel real-time dynamic magnetic resonance imaging in combination with static measurements for gastric emptying and training of an automated deep-learning-based segmentation pipeline. Prospective. The study included 36 healthy volunteers (20 female, mean 24 ± 3 years) and three patients with diagnosed Crohn's disease. Participants ingested water to assess fasting motility and pineapple juice for the postprandial state. 3 T, 3D spoiled gradient echo (GRE) sequence and real-time spoiled GRE. Gastric emptying was measured by using the gastric volume, while motility was analyzed by tracking changes in the antrum's cross-sectional area and applying Fast Fourier Transformation. Segmentations were performed using a trained semantic segmentation model. Linear Mixed Model with continuous dependent variables and fixed effects. Models included a random intercept for participants. Statistical significance was defined as p = 0.05. The method enabled volumetric analysis of gastric content from 3D breath-hold static acquisition and time-resolved quantification of peristaltic parameters from real-time FLASH2 imaging at high temporal resolution (here 6.24 fps). Water emptied rapidly and exponentially (t<sub>1/2</sub> = 14.77 ± 10.55 min), while juice showed slower emptying (t<sub>1/2</sub> = 64.24 ± 11.87 min). Contraction frequencies (fasted: 2.76 ± 0.43 cpm, fed: 2.89 ± 0.43 cpm) and velocities (fasted: 1.67 ± 0.38 mm/s, fed: 1.72 ± 0.37 mm/s) were within physiological ranges, with fasting conditions characterized by stronger occlusion compared to the fed. Measurements taken from three patients proved that the workflow could be used in a clinical context. Real-time MRI with AI-based analysis enabled quantitative assessment of gastric emptying and motility, revealing physiological peristaltic parameters and state-dependent differences in occlusion. 2. Stage 1.