Sort by:
Page 1 of 12 results

Using deep learning methods to shorten acquisition time in children's renal cortical imaging

Gan, C., Niu, P., Pan, B., Chen, X., Xu, L., Huang, K., Chen, H., Wang, Q., Ding, L., Yin, Y., Wu, S., Gong, N.-j.

medrxiv logopreprintAug 13 2025
PurposeThis study evaluates the capability of diffusion-based generative models to reconstruct diagnostic-quality renal cortical images from reduced-acquisition-time pediatric 99mTc-DMSA scintigraphy. Materials and MethodsA prospective study was conducted on 99mTc-DMSA scintigraphic data from consecutive pediatric patients with suspected urinary tract infections (UTIs) acquired between November 2023 and October 2024. A diffusion model SR3 was trained to reconstruct standard-quality images from simulated reduced-count data. Performance was benchmarked against U-Net, U2-Net, Restormer, and a Poisson-based variant of SR3 (PoissonSR3). Quantitative assessment employed peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), Frechet inception distance (FID), and learned perceptual image patch similarity (LPIPS). Renal contrast and anatomic fidelity were assessed using the target-to-background ratio (TBR) and the Dice similarity coefficient respectively. Wilcoxon signed-rank tests were used for statistical analysis. ResultsThe training cohort comprised 94 participants (mean age 5.16{+/-}3.90 years; 48 male) with corresponding Poisson-downsampled images, while the test cohort included 36 patients (mean age 6.39{+/-}3.16 years; 14 male). SR3 outperformed all models, achieving the highest PSNR (30.976{+/-}2.863, P<.001), SSIM (0.760{+/-}0.064, P<.001), FID (25.687{+/-}16.223, P<.001), and LPIPS (0.055{+/-}0.022, P<.001). Further, SR3 maintained excellent renal contrast (TBR: left kidney 7.333{+/-}2.176; right kidney 7.156{+/-}1.808) and anatomical consistency (Dice coefficient: left kidney 0.749{+/-}0.200; right kidney 0.745{+/-}0.176), representing significant improvements over the fast scan (all P < .001). While Restormer, U-Net, and PoissonSR3 showed statistically significant improvements across all metrics, U2-Net exhibited limited improvement restricted to SSIM and left kidney TBR (P < .001). ConclusionSR3 enables high-quality reconstruction of 99mTc-DMSA images from 4-fold accelerated acquisitions, demonstrating potential for substantial reduction in imaging duration while preserving both diagnostic image quality and renal anatomical integrity.

Machine Learning-Based Reconstruction of 2D MRI for Quantitative Morphometry in Epilepsy

Ratcliffe, C., Taylor, P. N., de Bezenac, C., Das, K., Biswas, S., Marson, A., Keller, S. S.

medrxiv logopreprintAug 6 2025
IntroductionStructural neuroimaging analyses require research quality images, acquired with costly MRI acquisitions. Isotropic (3D-T1) images are desirable for quantitative analyses, however a routine compromise in the clinical setting is to acquire anisotropic (2D-T1) analogues for qualitative visual inspection. ML (Machine learning-based) software have shown promise in addressing some of the limitations of 2D-T1 scans in research applications, yet their efficacy in quantitative research is generally poorly understood. Pathology-related abnormalities of the subcortical structures have previously been identified in idiopathic generalised epilepsy (IGE), which have been overlooked based on visual inspection, through the use of quantitative morphometric analyses. As such, IGE biomarkers present a suitable model in which to evaluate the applicability of image preprocessing methods. This study therefore explores subcortical structural biomarkers of IGE, first in our silver standard 3D-T1 scans, then in 2D-T1 scans that were either untransformed, resampled using a classical interpolation approach, or synthesised with a resolution and contrast agnostic ML model (the latter of which is compared to a separate model). Methods2D-T1 and 3D-T1 MRI scans were acquired during the same scanning session for 33 individuals with drug-responsive IGE (age mean 32.16 {+/-} SD = 14.20, male n = 14) and 42 individuals with drug-resistant IGE (31.76 {+/-} 11.12, 17), all diagnosed at the Walton Centre NHS Foundation Trust Liverpool, alongside 39 age- and sex-matched healthy controls (32.32 {+/-} 8.65, 16). The untransformed 2D-T1 scans were resampled into isotropic images using NiBabel (res-T1), and preprocessed into synthetic isotropic images using SynthSR (syn-T1). For the 3D-T1, 2D-T1, res-T1, and syn-T1 images, the recon-all command from FreeSurfer 8.0.0 was used to create parcellations of 174 anatomical regions (equivalent to the 174 regional parcellations provided as part of the DL+DiReCT pipeline), defined by the aseg and Destrieux atlases, and FSL run_first_all was used to segment subcortical surface shapes. The new ML FreeSurfer pipeline, recon-all-clinical, was also tested in the 2D-T1, 3D-T1, and res-T1 images. As a model comparison for SynthSR, the DL+DiReCT pipeline was used to provide segmentations of the 2D-T1 and res-T1 images, including estimates of regional volume and thickness. Spatial overlap and intraclass correlations between the morphometrics of the eight resulting parcellations were first determined, then subcortical surface shape abnormalities associated with IGE were identified by comparing the FSL run_first_all outputs of patients with controls. ResultsWhen standardised to the metrics derived from the 3D-T1 scans, cortical volume and thickness estimates trended lower for the 2D-T1, res-T1, syn-T1, and DL+DiReCT outputs, whereas subcortical volume estimates were more coherent. Dice coefficients revealed an acceptable spatial similarity between the cortices of the 3D-T1 scans and the other images overall, and was higher in the subcortical structures. Intraclass correlation coefficients were consistently lowest when metrics were computed for model-derived inputs, and estimates of thickness were less similar to the ground truth than those of volume. For the people with epilepsy, the 3D-T1 scans showed significant surface deflations across various subcortical structures when compared to healthy controls. Analysis of the 2D-T1 scans enabled the reliable detection of a subset of subcortical abnormalities, whereas analyses of the res-T1 and syn-T1 images were more prone to false-positive results. ConclusionsResampling and ML image synthesis methods do not currently attenuate partial volume effects resulting from low through plane resolution in anisotropic MRI scans, instead quantitative analyses using 2D-T1 scans should be interpreted with caution, and researchers should consider the potential implications of preprocessing. The recon-all-clinical pipeline is promising, but requires further evaluation, especially when considered as an alternative to the classical pipeline. Key PointsO_LISurface deviations indicative of regional atrophy and hypertrophy were identified in people with idiopathic generalised epilepsy. C_LIO_LIPartial volume effects are likely to attenuate subtle morphometric abnormalities, increasing the likelihood of erroneous inference. C_LIO_LIPriors in synthetic image creation models may render them insensitive to subtle biomarkers. C_LIO_LIResampling and machine-learning based image synthesis are not currently replacements for research quality acquisitions in quantitative MRI research. C_LIO_LIThe results of studies using synthetic images should be interpreted in a separate context to those using untransformed data. C_LI
Page 1 of 12 results
Show
per page
1

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.