Sort by:
Page 1 of 983 results
Next

Nuclear Diffusion Models for Low-Rank Background Suppression in Videos

Tristan S. W. Stevens, Oisín Nolan, Jean-Luc Robert, Ruud J. G. van Sloun

arxiv logopreprintSep 25 2025
Video sequences often contain structured noise and background artifacts that obscure dynamic content, posing challenges for accurate analysis and restoration. Robust principal component methods address this by decomposing data into low-rank and sparse components. Still, the sparsity assumption often fails to capture the rich variability present in real video data. To overcome this limitation, a hybrid framework that integrates low-rank temporal modeling with diffusion posterior sampling is proposed. The proposed method, Nuclear Diffusion, is evaluated on a real-world medical imaging problem, namely cardiac ultrasound dehazing, and demonstrates improved dehazing performance compared to traditional RPCA concerning contrast enhancement (gCNR) and signal preservation (KS statistic). These results highlight the potential of combining model-based temporal models with deep generative priors for high-fidelity video restoration.

Influence of Classification Task and Distribution Shift Type on OOD Detection in Fetal Ultrasound

Chun Kit Wong, Anders N. Christensen, Cosmin I. Bercea, Julia A. Schnabel, Martin G. Tolsgaard, Aasa Feragen

arxiv logopreprintSep 22 2025
Reliable out-of-distribution (OOD) detection is important for safe deployment of deep learning models in fetal ultrasound amidst heterogeneous image characteristics and clinical settings. OOD detection relies on estimating a classification model's uncertainty, which should increase for OOD samples. While existing research has largely focused on uncertainty quantification methods, this work investigates the impact of the classification task itself. Through experiments with eight uncertainty quantification methods across four classification tasks, we demonstrate that OOD detection performance significantly varies with the task, and that the best task depends on the defined ID-OOD criteria; specifically, whether the OOD sample is due to: i) an image characteristic shift or ii) an anatomical feature shift. Furthermore, we reveal that superior OOD detection does not guarantee optimal abstained prediction, underscoring the necessity to align task selection and uncertainty strategies with the specific downstream application in medical image analysis.

Echo-Path: Pathology-Conditioned Echo Video Generation

Kabir Hamzah Muhammad, Marawan Elbatel, Yi Qin, Xiaomeng Li

arxiv logopreprintSep 21 2025
Cardiovascular diseases (CVDs) remain the leading cause of mortality globally, and echocardiography is critical for diagnosis of both common and congenital cardiac conditions. However, echocardiographic data for certain pathologies are scarce, hindering the development of robust automated diagnosis models. In this work, we propose Echo-Path, a novel generative framework to produce echocardiogram videos conditioned on specific cardiac pathologies. Echo-Path can synthesize realistic ultrasound video sequences that exhibit targeted abnormalities, focusing here on atrial septal defect (ASD) and pulmonary arterial hypertension (PAH). Our approach introduces a pathology-conditioning mechanism into a state-of-the-art echo video generator, allowing the model to learn and control disease-specific structural and motion patterns in the heart. Quantitative evaluation demonstrates that the synthetic videos achieve low distribution distances, indicating high visual fidelity. Clinically, the generated echoes exhibit plausible pathology markers. Furthermore, classifiers trained on our synthetic data generalize well to real data and, when used to augment real training sets, it improves downstream diagnosis of ASD and PAH by 7\% and 8\% respectively. Code, weights and dataset are available here https://github.com/Marshall-mk/EchoPathv1

Accurate Thyroid Cancer Classification using a Novel Binary Pattern Driven Local Discrete Cosine Transform Descriptor

Saurabh Saini, Kapil Ahuja, Marc C. Steinbach, Thomas Wick

arxiv logopreprintSep 19 2025
In this study, we develop a new CAD system for accurate thyroid cancer classification with emphasis on feature extraction. Prior studies have shown that thyroid texture is important for segregating the thyroid ultrasound images into different classes. Based upon our experience with breast cancer classification, we first conjuncture that the Discrete Cosine Transform (DCT) is the best descriptor for capturing textural features. Thyroid ultrasound images are particularly challenging as the gland is surrounded by multiple complex anatomical structures leading to variations in tissue density. Hence, we second conjuncture the importance of localization and propose that the Local DCT (LDCT) descriptor captures the textural features best in this context. Another disadvantage of complex anatomy around the thyroid gland is scattering of ultrasound waves resulting in noisy and unclear textures. Hence, we third conjuncture that one image descriptor is not enough to fully capture the textural features and propose the integration of another popular texture capturing descriptor (Improved Local Binary Pattern, ILBP) with LDCT. ILBP is known to be noise resilient as well. We term our novel descriptor as Binary Pattern Driven Local Discrete Cosine Transform (BPD-LDCT). Final classification is carried out using a non-linear SVM. The proposed CAD system is evaluated on the only two publicly available thyroid cancer datasets, namely TDID and AUITD. The evaluation is conducted in two stages. In Stage I, thyroid nodules are categorized as benign or malignant. In Stage II, the malignant cases are further sub-classified into TI-RADS (4) and TI-RADS (5). For Stage I classification, our proposed model demonstrates exceptional performance of nearly 100% on TDID and 97% on AUITD. In Stage II classification, the proposed model again attains excellent classification of close to 100% on TDID and 99% on AUITD.

Prostate Capsule Segmentation from Micro-Ultrasound Images using Adaptive Focal Loss

Kaniz Fatema, Vaibhav Thakur, Emad A. Mohammed

arxiv logopreprintSep 19 2025
Micro-ultrasound (micro-US) is a promising imaging technique for cancer detection and computer-assisted visualization. This study investigates prostate capsule segmentation using deep learning techniques from micro-US images, addressing the challenges posed by the ambiguous boundaries of the prostate capsule. Existing methods often struggle in such cases, motivating the development of a tailored approach. This study introduces an adaptive focal loss function that dynamically emphasizes both hard and easy regions, taking into account their respective difficulty levels and annotation variability. The proposed methodology has two primary strategies: integrating a standard focal loss function as a baseline to design an adaptive focal loss function for proper prostate capsule segmentation. The focal loss baseline provides a robust foundation, incorporating class balancing and focusing on examples that are difficult to classify. The adaptive focal loss offers additional flexibility, addressing the fuzzy region of the prostate capsule and annotation variability by dilating the hard regions identified through discrepancies between expert and non-expert annotations. The proposed method dynamically adjusts the segmentation model's weights better to identify the fuzzy regions of the prostate capsule. The proposed adaptive focal loss function demonstrates superior performance, achieving a mean dice coefficient (DSC) of 0.940 and a mean Hausdorff distance (HD) of 1.949 mm in the testing dataset. These results highlight the effectiveness of integrating advanced loss functions and adaptive techniques into deep learning models. This enhances the accuracy of prostate capsule segmentation in micro-US images, offering the potential to improve clinical decision-making in prostate cancer diagnosis and treatment planning.

A Fully Open and Generalizable Foundation Model for Ultrasound Clinical Applications

Hongyuan Zhang, Yuheng Wu, Mingyang Zhao, Zhiwei Chen, Rebecca Li, Fei Zhu, Haohan Zhao, Xiaohua Yuan, Meng Yang, Chunli Qiu, Xiang Cong, Haiyan Chen, Lina Luan, Randolph H. L. Wong, Huai Liao, Colin A Graham, Shi Chang, Guowei Tao, Dong Yi, Zhen Lei, Nassir Navab, Sebastien Ourselin, Jiebo Luo, Hongbin Liu, Gaofeng Meng

arxiv logopreprintSep 15 2025
Artificial intelligence (AI) that can effectively learn ultrasound representations by integrating multi-source data holds significant promise for advancing clinical care. However, the scarcity of large labeled datasets in real-world clinical environments and the limited generalizability of task-specific models have hindered the development of generalizable clinical AI models for ultrasound applications. In this study, we present EchoCare, a novel ultrasound foundation model for generalist clinical use, developed via self-supervised learning on our curated, publicly available, large-scale dataset EchoCareData. EchoCareData comprises 4.5 million ultrasound images, sourced from over 23 countries across 5 continents and acquired via a diverse range of distinct imaging devices, thus encompassing global cohorts that are multi-center, multi-device, and multi-ethnic. Unlike prior studies that adopt off-the-shelf vision foundation model architectures, we introduce a hierarchical classifier into EchoCare to enable joint learning of pixel-level and representation-level features, capturing both global anatomical contexts and local ultrasound characteristics. With minimal training, EchoCare outperforms state-of-the-art comparison models across 10 representative ultrasound benchmarks of varying diagnostic difficulties, spanning disease diagnosis, lesion segmentation, organ detection, landmark prediction, quantitative regression, imaging enhancement and report generation. The code and pretrained model are publicly released, rendering EchoCare accessible for fine-tuning and local adaptation, supporting extensibility to additional applications. EchoCare provides a fully open and generalizable foundation model to boost the development of AI technologies for diverse clinical ultrasound applications.

Pseudo-D: Informing Multi-View Uncertainty Estimation with Calibrated Neural Training Dynamics

Ang Nan Gu, Michael Tsang, Hooman Vaseli, Purang Abolmaesumi, Teresa Tsang

arxiv logopreprintSep 15 2025
Computer-aided diagnosis systems must make critical decisions from medical images that are often noisy, ambiguous, or conflicting, yet today's models are trained on overly simplistic labels that ignore diagnostic uncertainty. One-hot labels erase inter-rater variability and force models to make overconfident predictions, especially when faced with incomplete or artifact-laden inputs. We address this gap by introducing a novel framework that brings uncertainty back into the label space. Our method leverages neural network training dynamics (NNTD) to assess the inherent difficulty of each training sample. By aggregating and calibrating model predictions during training, we generate uncertainty-aware pseudo-labels that reflect the ambiguity encountered during learning. This label augmentation approach is architecture-agnostic and can be applied to any supervised learning pipeline to enhance uncertainty estimation and robustness. We validate our approach on a challenging echocardiography classification benchmark, demonstrating superior performance over specialized baselines in calibration, selective classification, and multi-view fusion.

DualTrack: Sensorless 3D Ultrasound needs Local and Global Context

Paul F. R. Wilson, Matteo Ronchetti, Rüdiger Göbl, Viktoria Markova, Sebastian Rosenzweig, Raphael Prevost, Parvin Mousavi, Oliver Zettinig

arxiv logopreprintSep 11 2025
Three-dimensional ultrasound (US) offers many clinical advantages over conventional 2D imaging, yet its widespread adoption is limited by the cost and complexity of traditional 3D systems. Sensorless 3D US, which uses deep learning to estimate a 3D probe trajectory from a sequence of 2D US images, is a promising alternative. Local features, such as speckle patterns, can help predict frame-to-frame motion, while global features, such as coarse shapes and anatomical structures, can situate the scan relative to anatomy and help predict its general shape. In prior approaches, global features are either ignored or tightly coupled with local feature extraction, restricting the ability to robustly model these two complementary aspects. We propose DualTrack, a novel dual-encoder architecture that leverages decoupled local and global encoders specialized for their respective scales of feature extraction. The local encoder uses dense spatiotemporal convolutions to capture fine-grained features, while the global encoder utilizes an image backbone (e.g., a 2D CNN or foundation model) and temporal attention layers to embed high-level anatomical features and long-range dependencies. A lightweight fusion module then combines these features to estimate the trajectory. Experimental results on a large public benchmark show that DualTrack achieves state-of-the-art accuracy and globally consistent 3D reconstructions, outperforming previous methods and yielding an average reconstruction error below 5 mm.

LD-ViCE: Latent Diffusion Model for Video Counterfactual Explanations

Payal Varshney, Adriano Lucieri, Christoph Balada, Sheraz Ahmed, Andreas Dengel

arxiv logopreprintSep 10 2025
Video-based AI systems are increasingly adopted in safety-critical domains such as autonomous driving and healthcare. However, interpreting their decisions remains challenging due to the inherent spatiotemporal complexity of video data and the opacity of deep learning models. Existing explanation techniques often suffer from limited temporal coherence, insufficient robustness, and a lack of actionable causal insights. Current counterfactual explanation methods typically do not incorporate guidance from the target model, reducing semantic fidelity and practical utility. We introduce Latent Diffusion for Video Counterfactual Explanations (LD-ViCE), a novel framework designed to explain the behavior of video-based AI models. Compared to previous approaches, LD-ViCE reduces the computational costs of generating explanations by operating in latent space using a state-of-the-art diffusion model, while producing realistic and interpretable counterfactuals through an additional refinement step. Our experiments demonstrate the effectiveness of LD-ViCE across three diverse video datasets, including EchoNet-Dynamic (cardiac ultrasound), FERV39k (facial expression), and Something-Something V2 (action recognition). LD-ViCE outperforms a recent state-of-the-art method, achieving an increase in R2 score of up to 68% while reducing inference time by half. Qualitative analysis confirms that LD-ViCE generates semantically meaningful and temporally coherent explanations, offering valuable insights into the target model behavior. LD-ViCE represents a valuable step toward the trustworthy deployment of AI in safety-critical domains.

XBusNet: Text-Guided Breast Ultrasound Segmentation via Multimodal Vision-Language Learning

Raja Mallina, Bryar Shareef

arxiv logopreprintSep 8 2025
Background: Precise breast ultrasound (BUS) segmentation supports reliable measurement, quantitative analysis, and downstream classification, yet remains difficult for small or low-contrast lesions with fuzzy margins and speckle noise. Text prompts can add clinical context, but directly applying weakly localized text-image cues (e.g., CAM/CLIP-derived signals) tends to produce coarse, blob-like responses that smear boundaries unless additional mechanisms recover fine edges. Methods: We propose XBusNet, a novel dual-prompt, dual-branch multimodal model that combines image features with clinically grounded text. A global pathway based on a CLIP Vision Transformer encodes whole-image semantics conditioned on lesion size and location, while a local U-Net pathway emphasizes precise boundaries and is modulated by prompts that describe shape, margin, and Breast Imaging Reporting and Data System (BI-RADS) terms. Prompts are assembled automatically from structured metadata, requiring no manual clicks. We evaluate on the Breast Lesions USG (BLU) dataset using five-fold cross-validation. Primary metrics are Dice and Intersection over Union (IoU); we also conduct size-stratified analyses and ablations to assess the roles of the global and local paths and the text-driven modulation. Results: XBusNet achieves state-of-the-art performance on BLU, with mean Dice of 0.8765 and IoU of 0.8149, outperforming six strong baselines. Small lesions show the largest gains, with fewer missed regions and fewer spurious activations. Ablation studies show complementary contributions of global context, local boundary modeling, and prompt-based modulation. Conclusions: A dual-prompt, dual-branch multimodal design that merges global semantics with local precision yields accurate BUS segmentation masks and improves robustness for small, low-contrast lesions.
Page 1 of 983 results
Show
per page

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.