Sort by:
Page 1 of 219 results
Next

SwinECAT: A Transformer-based fundus disease classification model with Shifted Window Attention and Efficient Channel Attention

Peiran Gu, Teng Yao, Mengshen He, Fuhao Duan, Feiyan Liu, RenYuan Peng, Bao Ge

arxiv logopreprintJul 29 2025
In recent years, artificial intelligence has been increasingly applied in the field of medical imaging. Among these applications, fundus image analysis presents special challenges, including small lesion areas in certain fundus diseases and subtle inter-disease differences, which can lead to reduced prediction accuracy and overfitting in the models. To address these challenges, this paper proposes the Transformer-based model SwinECAT, which combines the Shifted Window (Swin) Attention with the Efficient Channel Attention (ECA) Attention. SwinECAT leverages the Swin Attention mechanism in the Swin Transformer backbone to effectively capture local spatial structures and long-range dependencies within fundus images. The lightweight ECA mechanism is incorporated to guide the SwinECAT's attention toward critical feature channels, enabling more discriminative feature representation. In contrast to previous studies that typically classify fundus images into 4 to 6 categories, this work expands fundus disease classification to 9 distinct types, thereby enhancing the granularity of diagnosis. We evaluate our method on the Eye Disease Image Dataset (EDID) containing 16,140 fundus images for 9-category classification. Experimental results demonstrate that SwinECAT achieves 88.29\% accuracy, with weighted F1-score of 0.88 and macro F1-score of 0.90. The classification results of our proposed model SwinECAT significantly outperform the baseline Swin Transformer and multiple compared baseline models. To our knowledge, this represents the highest reported performance for 9-category classification on this public dataset.

Information Entropy-Based Framework for Quantifying Tortuosity in Meibomian Gland Uneven Atrophy

Kesheng Wang, Xiaoyu Chen, Chunlei He, Fenfen Li, Xinxin Yu, Dexing Kong, Shoujun Huang, Qi Dai

arxiv logopreprintJul 24 2025
In the medical image analysis field, precise quantification of curve tortuosity plays a critical role in the auxiliary diagnosis and pathological assessment of various diseases. In this study, we propose a novel framework for tortuosity quantification and demonstrate its effectiveness through the evaluation of meibomian gland atrophy uniformity,serving as a representative application scenario. We introduce an information entropy-based tortuosity quantification framework that integrates probability modeling with entropy theory and incorporates domain transformation of curve data. Unlike traditional methods such as curvature or arc-chord ratio, this approach evaluates the tortuosity of a target curve by comparing it to a designated reference curve. Consequently, it is more suitable for tortuosity assessment tasks in medical data where biologically plausible reference curves are available, providing a more robust and objective evaluation metric without relying on idealized straight-line comparisons. First, we conducted numerical simulation experiments to preliminarily assess the stability and validity of the method. Subsequently, the framework was applied to quantify the spatial uniformity of meibomian gland atrophy and to analyze the difference in this uniformity between \textit{Demodex}-negative and \textit{Demodex}-positive patient groups. The results demonstrated a significant difference in tortuosity-based uniformity between the two groups, with an area under the curve of 0.8768, sensitivity of 0.75, and specificity of 0.93. These findings highlight the clinical utility of the proposed framework in curve tortuosity analysis and its potential as a generalizable tool for quantitative morphological evaluation in medical diagnostics.

MaskedCLIP: Bridging the Masked and CLIP Space for Semi-Supervised Medical Vision-Language Pre-training

Lei Zhu, Jun Zhou, Rick Siow Mong Goh, Yong Liu

arxiv logopreprintJul 23 2025
Foundation models have recently gained tremendous popularity in medical image analysis. State-of-the-art methods leverage either paired image-text data via vision-language pre-training or unpaired image data via self-supervised pre-training to learn foundation models with generalizable image features to boost downstream task performance. However, learning foundation models exclusively on either paired or unpaired image data limits their ability to learn richer and more comprehensive image features. In this paper, we investigate a novel task termed semi-supervised vision-language pre-training, aiming to fully harness the potential of both paired and unpaired image data for foundation model learning. To this end, we propose MaskedCLIP, a synergistic masked image modeling and contrastive language-image pre-training framework for semi-supervised vision-language pre-training. The key challenge in combining paired and unpaired image data for learning a foundation model lies in the incompatible feature spaces derived from these two types of data. To address this issue, we propose to connect the masked feature space with the CLIP feature space with a bridge transformer. In this way, the more semantic specific CLIP features can benefit from the more general masked features for semantic feature extraction. We further propose a masked knowledge distillation loss to distill semantic knowledge of original image features in CLIP feature space back to the predicted masked image features in masked feature space. With this mutually interactive design, our framework effectively leverages both paired and unpaired image data to learn more generalizable image features for downstream tasks. Extensive experiments on retinal image analysis demonstrate the effectiveness and data efficiency of our method.

A Lightweight and Robust Framework for Real-Time Colorectal Polyp Detection Using LOF-Based Preprocessing and YOLO-v11n

Saadat Behzadi, Danial Sharifrazi, Bita Mesbahzadeh, Javad Hassannataj Joloudarid, Roohallah Alizadehsani

arxiv logopreprintJul 14 2025
Objectives: Timely and accurate detection of colorectal polyps plays a crucial role in diagnosing and preventing colorectal cancer, a major cause of mortality worldwide. This study introduces a new, lightweight, and efficient framework for polyp detection that combines the Local Outlier Factor (LOF) algorithm for filtering noisy data with the YOLO-v11n deep learning model. Study design: An experimental study leveraging deep learning and outlier removal techniques across multiple public datasets. Methods: The proposed approach was tested on five diverse and publicly available datasets: CVC-ColonDB, CVC-ClinicDB, Kvasir-SEG, ETIS, and EndoScene. Since these datasets originally lacked bounding box annotations, we converted their segmentation masks into suitable detection labels. To enhance the robustness and generalizability of our model, we apply 5-fold cross-validation and remove anomalous samples using the LOF method configured with 30 neighbors and a contamination ratio of 5%. Cleaned data are then fed into YOLO-v11n, a fast and resource-efficient object detection architecture optimized for real-time applications. We train the model using a combination of modern augmentation strategies to improve detection accuracy under diverse conditions. Results: Our approach significantly improves polyp localization performance, achieving a precision of 95.83%, recall of 91.85%, F1-score of 93.48%, [email protected] of 96.48%, and [email protected]:0.95 of 77.75%. Compared to previous YOLO-based methods, our model demonstrates enhanced accuracy and efficiency. Conclusions: These results suggest that the proposed method is well-suited for real-time colonoscopy support in clinical settings. Overall, the study underscores how crucial data preprocessing and model efficiency are when designing effective AI systems for medical imaging.

Disentanglement and Assessment of Shortcuts in Ophthalmological Retinal Imaging Exams

Leonor Fernandes, Tiago Gonçalves, João Matos, Luis Filipe Nakayama, Jaime S. Cardoso

arxiv logopreprintJul 13 2025
Diabetic retinopathy (DR) is a leading cause of vision loss in working-age adults. While screening reduces the risk of blindness, traditional imaging is often costly and inaccessible. Artificial intelligence (AI) algorithms present a scalable diagnostic solution, but concerns regarding fairness and generalization persist. This work evaluates the fairness and performance of image-trained models in DR prediction, as well as the impact of disentanglement as a bias mitigation technique, using the diverse mBRSET fundus dataset. Three models, ConvNeXt V2, DINOv2, and Swin V2, were trained on macula images to predict DR and sensitive attributes (SAs) (e.g., age and gender/sex). Fairness was assessed between subgroups of SAs, and disentanglement was applied to reduce bias. All models achieved high DR prediction performance in diagnosing (up to 94% AUROC) and could reasonably predict age and gender/sex (91% and 77% AUROC, respectively). Fairness assessment suggests disparities, such as a 10% AUROC gap between age groups in DINOv2. Disentangling SAs from DR prediction had varying results, depending on the model selected. Disentanglement improved DINOv2 performance (2% AUROC gain), but led to performance drops in ConvNeXt V2 and Swin V2 (7% and 3%, respectively). These findings highlight the complexity of disentangling fine-grained features in fundus imaging and emphasize the importance of fairness in medical imaging AI to ensure equitable and reliable healthcare solutions.

Capsule-ConvKAN: A Hybrid Neural Approach to Medical Image Classification

Laura Pituková, Peter Sinčák, László József Kovács

arxiv logopreprintJul 8 2025
This study conducts a comprehensive comparison of four neural network architectures: Convolutional Neural Network, Capsule Network, Convolutional Kolmogorov--Arnold Network, and the newly proposed Capsule--Convolutional Kolmogorov--Arnold Network. The proposed Capsule-ConvKAN architecture combines the dynamic routing and spatial hierarchy capabilities of Capsule Network with the flexible and interpretable function approximation of Convolutional Kolmogorov--Arnold Networks. This novel hybrid model was developed to improve feature representation and classification accuracy, particularly in challenging real-world biomedical image data. The architectures were evaluated on a histopathological image dataset, where Capsule-ConvKAN achieved the highest classification performance with an accuracy of 91.21\%. The results demonstrate the potential of the newly introduced Capsule-ConvKAN in capturing spatial patterns, managing complex features, and addressing the limitations of traditional convolutional models in medical image classification.

Efficacy of Image Similarity as a Metric for Augmenting Small Dataset Retinal Image Segmentation

Thomas Wallace, Ik Siong Heng, Senad Subasic, Chris Messenger

arxiv logopreprintJul 7 2025
Synthetic images are an option for augmenting limited medical imaging datasets to improve the performance of various machine learning models. A common metric for evaluating synthetic image quality is the Fr\'echet Inception Distance (FID) which measures the similarity of two image datasets. In this study we evaluate the relationship between this metric and the improvement which synthetic images, generated by a Progressively Growing Generative Adversarial Network (PGGAN), grant when augmenting Diabetes-related Macular Edema (DME) intraretinal fluid segmentation performed by a U-Net model with limited amounts of training data. We find that the behaviour of augmenting with standard and synthetic images agrees with previously conducted experiments. Additionally, we show that dissimilar (high FID) datasets do not improve segmentation significantly. As FID between the training and augmenting datasets decreases, the augmentation datasets are shown to contribute to significant and robust improvements in image segmentation. Finally, we find that there is significant evidence to suggest that synthetic and standard augmentations follow separate log-normal trends between FID and improvements in model performance, with synthetic data proving more effective than standard augmentation techniques. Our findings show that more similar datasets (lower FID) will be more effective at improving U-Net performance, however, the results also suggest that this improvement may only occur when images are sufficiently dissimilar.

Sequential Attention-based Sampling for Histopathological Analysis

Tarun G, Naman Malpani, Gugan Thoppe, Sridharan Devarajan

arxiv logopreprintJul 7 2025
Deep neural networks are increasingly applied for automated histopathology. Yet, whole-slide images (WSIs) are often acquired at gigapixel sizes, rendering it computationally infeasible to analyze them entirely at high resolution. Diagnostic labels are largely available only at the slide-level, because expert annotation of images at a finer (patch) level is both laborious and expensive. Moreover, regions with diagnostic information typically occupy only a small fraction of the WSI, making it inefficient to examine the entire slide at full resolution. Here, we propose SASHA -- {\it S}equential {\it A}ttention-based {\it S}ampling for {\it H}istopathological {\it A}nalysis -- a deep reinforcement learning approach for efficient analysis of histopathological images. First, SASHA learns informative features with a lightweight hierarchical, attention-based multiple instance learning (MIL) model. Second, SASHA samples intelligently and zooms selectively into a small fraction (10-20\%) of high-resolution patches, to achieve reliable diagnosis. We show that SASHA matches state-of-the-art methods that analyze the WSI fully at high-resolution, albeit at a fraction of their computational and memory costs. In addition, it significantly outperforms competing, sparse sampling methods. We propose SASHA as an intelligent sampling model for medical imaging challenges that involve automated diagnosis with exceptionally large images containing sparsely informative features.

PhotIQA: A photoacoustic image data set with image quality ratings

Anna Breger, Janek Gröhl, Clemens Karner, Thomas R Else, Ian Selby, Jonathan Weir-McCall, Carola-Bibiane Schönlieb

arxiv logopreprintJul 4 2025
Image quality assessment (IQA) is crucial in the evaluation stage of novel algorithms operating on images, including traditional and machine learning based methods. Due to the lack of available quality-rated medical images, most commonly used IQA methods employing reference images (i.e. full-reference IQA) have been developed and tested for natural images. Reported application inconsistencies arising when employing such measures for medical images are not surprising, as they rely on different properties than natural images. In photoacoustic imaging (PAI), especially, standard benchmarking approaches for assessing the quality of image reconstructions are lacking. PAI is a multi-physics imaging modality, in which two inverse problems have to be solved, which makes the application of IQA measures uniquely challenging due to both, acoustic and optical, artifacts. To support the development and testing of full- and no-reference IQA measures we assembled PhotIQA, a data set consisting of 1134 reconstructed photoacoustic (PA) images that were rated by 2 experts across five quality properties (overall quality, edge visibility, homogeneity, inclusion and background intensity), where the detailed rating enables usage beyond PAI. To allow full-reference assessment, highly characterised imaging test objects were used, providing a ground truth. Our baseline experiments show that HaarPSI$_{med}$ significantly outperforms SSIM in correlating with the quality ratings (SRCC: 0.83 vs. 0.62). The dataset is publicly available at https://doi.org/10.5281/zenodo.13325196.

Topological Signatures vs. Gradient Histograms: A Comparative Study for Medical Image Classification

Faisal Ahmed, Mohammad Alfrad Nobel Bhuiyan

arxiv logopreprintJul 2 2025
We present the first comparative study of two fundamentally distinct feature extraction techniques: Histogram of Oriented Gradients (HOG) and Topological Data Analysis (TDA), for medical image classification using retinal fundus images. HOG captures local texture and edge patterns through gradient orientation histograms, while TDA, using cubical persistent homology, extracts high-level topological signatures that reflect the global structure of pixel intensities. We evaluate both methods on the large APTOS dataset for two classification tasks: binary detection (normal versus diabetic retinopathy) and five-class diabetic retinopathy severity grading. From each image, we extract 26244 HOG features and 800 TDA features, using them independently to train seven classical machine learning models with 10-fold cross-validation. XGBoost achieved the best performance in both cases: 94.29 percent accuracy (HOG) and 94.18 percent (TDA) on the binary task; 74.41 percent (HOG) and 74.69 percent (TDA) on the multi-class task. Our results show that both methods offer competitive performance but encode different structural aspects of the images. This is the first work to benchmark gradient-based and topological features on retinal imagery. The techniques are interpretable, applicable to other medical imaging domains, and suitable for integration into deep learning pipelines.
Page 1 of 219 results
Show
per page
12»

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.