Sort by:
Page 6 of 16157 results

Weighted Mean Frequencies: a handcraft Fourier feature for 4D Flow MRI segmentation

Simon Perrin, Sébastien Levilly, Huajun Sun, Harold Mouchère, Jean-Michel Serfaty

arxiv logopreprintJun 25 2025
In recent decades, the use of 4D Flow MRI images has enabled the quantification of velocity fields within a volume of interest and along the cardiac cycle. However, the lack of resolution and the presence of noise in these biomarkers are significant issues. As indicated by recent studies, it appears that biomarkers such as wall shear stress are particularly impacted by the poor resolution of vessel segmentation. The Phase Contrast Magnetic Resonance Angiography (PC-MRA) is the state-of-the-art method to facilitate segmentation. The objective of this work is to introduce a new handcraft feature that provides a novel visualisation of 4D Flow MRI images, which is useful in the segmentation task. This feature, termed Weighted Mean Frequencies (WMF), is capable of revealing the region in three dimensions where a voxel has been passed by pulsatile flow. Indeed, this feature is representative of the hull of all pulsatile velocity voxels. The value of the feature under discussion is illustrated by two experiments. The experiments involved segmenting 4D Flow MRI images using optimal thresholding and deep learning methods. The results obtained demonstrate a substantial enhancement in terms of IoU and Dice, with a respective increase of 0.12 and 0.13 in comparison with the PC-MRA feature, as evidenced by the deep learning task. This feature has the potential to yield valuable insights that could inform future segmentation processes in other vascular regions, such as the heart or the brain.

Patch2Loc: Learning to Localize Patches for Unsupervised Brain Lesion Detection

Hassan Baker, Austin J. Brockmeier

arxiv logopreprintJun 25 2025
Detecting brain lesions as abnormalities observed in magnetic resonance imaging (MRI) is essential for diagnosis and treatment. In the search of abnormalities, such as tumors and malformations, radiologists may benefit from computer-aided diagnostics that use computer vision systems trained with machine learning to segment normal tissue from abnormal brain tissue. While supervised learning methods require annotated lesions, we propose a new unsupervised approach (Patch2Loc) that learns from normal patches taken from structural MRI. We train a neural network model to map a patch back to its spatial location within a slice of the brain volume. During inference, abnormal patches are detected by the relatively higher error and/or variance of the location prediction. This generates a heatmap that can be integrated into pixel-wise methods to achieve finer-grained segmentation. We demonstrate the ability of our model to segment abnormal brain tissues by applying our approach to the detection of tumor tissues in MRI on T2-weighted images from BraTS2021 and MSLUB datasets and T1-weighted images from ATLAS and WMH datasets. We show that it outperforms the state-of-the art in unsupervised segmentation. The codebase for this work can be found on our \href{https://github.com/bakerhassan/Patch2Loc}{GitHub page}.

U-R-VEDA: Integrating UNET, Residual Links, Edge and Dual Attention, and Vision Transformer for Accurate Semantic Segmentation of CMRs

Racheal Mukisa, Arvind K. Bansal

arxiv logopreprintJun 25 2025
Artificial intelligence, including deep learning models, will play a transformative role in automated medical image analysis for the diagnosis of cardiac disorders and their management. Automated accurate delineation of cardiac images is the first necessary initial step for the quantification and automated diagnosis of cardiac disorders. In this paper, we propose a deep learning based enhanced UNet model, U-R-Veda, which integrates convolution transformations, vision transformer, residual links, channel-attention, and spatial attention, together with edge-detection based skip-connections for an accurate fully-automated semantic segmentation of cardiac magnetic resonance (CMR) images. The model extracts local-features and their interrelationships using a stack of combination convolution blocks, with embedded channel and spatial attention in the convolution block, and vision transformers. Deep embedding of channel and spatial attention in the convolution block identifies important features and their spatial localization. The combined edge information with channel and spatial attention as skip connection reduces information-loss during convolution transformations. The overall model significantly improves the semantic segmentation of CMR images necessary for improved medical image analysis. An algorithm for the dual attention module (channel and spatial attention) has been presented. Performance results show that U-R-Veda achieves an average accuracy of 95.2%, based on DSC metrics. The model outperforms the accuracy attained by other models, based on DSC and HD metrics, especially for the delineation of right-ventricle and left-ventricle-myocardium.

Radiomic fingerprints for knee MR images assessment

Yaxi Chen, Simin Ni, Shaheer U. Saeed, Aleksandra Ivanova, Rikin Hargunani, Jie Huang, Chaozong Liu, Yipeng Hu

arxiv logopreprintJun 25 2025
Accurate interpretation of knee MRI scans relies on expert clinical judgment, often with high variability and limited scalability. Existing radiomic approaches use a fixed set of radiomic features (the signature), selected at the population level and applied uniformly to all patients. While interpretable, these signatures are often too constrained to represent individual pathological variations. As a result, conventional radiomic-based approaches are found to be limited in performance, compared with recent end-to-end deep learning (DL) alternatives without using interpretable radiomic features. We argue that the individual-agnostic nature in current radiomic selection is not central to its intepretability, but is responsible for the poor generalization in our application. Here, we propose a novel radiomic fingerprint framework, in which a radiomic feature set (the fingerprint) is dynamically constructed for each patient, selected by a DL model. Unlike the existing radiomic signatures, our fingerprints are derived on a per-patient basis by predicting the feature relevance in a large radiomic feature pool, and selecting only those that are predictive of clinical conditions for individual patients. The radiomic-selecting model is trained simultaneously with a low-dimensional (considered relatively explainable) logistic regression for downstream classification. We validate our methods across multiple diagnostic tasks including general knee abnormalities, anterior cruciate ligament (ACL) tears, and meniscus tears, demonstrating comparable or superior diagnostic accuracy relative to state-of-the-art end-to-end DL models. More importantly, we show that the interpretability inherent in our approach facilitates meaningful clinical insights and potential biomarker discovery, with detailed discussion, quantitative and qualitative analysis of real-world clinical cases to evidence these advantages.

ReCoGNet: Recurrent Context-Guided Network for 3D MRI Prostate Segmentation

Ahmad Mustafa, Reza Rastegar, Ghassan AlRegib

arxiv logopreprintJun 24 2025
Prostate gland segmentation from T2-weighted MRI is a critical yet challenging task in clinical prostate cancer assessment. While deep learning-based methods have significantly advanced automated segmentation, most conventional approaches-particularly 2D convolutional neural networks (CNNs)-fail to leverage inter-slice anatomical continuity, limiting their accuracy and robustness. Fully 3D models offer improved spatial coherence but require large amounts of annotated data, which is often impractical in clinical settings. To address these limitations, we propose a hybrid architecture that models MRI sequences as spatiotemporal data. Our method uses a deep, pretrained DeepLabV3 backbone to extract high-level semantic features from each MRI slice and a recurrent convolutional head, built with ConvLSTM layers, to integrate information across slices while preserving spatial structure. This combination enables context-aware segmentation with improved consistency, particularly in data-limited and noisy imaging conditions. We evaluate our method on the PROMISE12 benchmark under both clean and contrast-degraded test settings. Compared to state-of-the-art 2D and 3D segmentation models, our approach demonstrates superior performance in terms of precision, recall, Intersection over Union (IoU), and Dice Similarity Coefficient (DSC), highlighting its potential for robust clinical deployment.

Systematic Review of Pituitary Gland and Pituitary Adenoma Automatic Segmentation Techniques in Magnetic Resonance Imaging

Mubaraq Yakubu, Navodini Wijethilake, Jonathan Shapey, Andrew King, Alexander Hammers

arxiv logopreprintJun 24 2025
Purpose: Accurate segmentation of both the pituitary gland and adenomas from magnetic resonance imaging (MRI) is essential for diagnosis and treatment of pituitary adenomas. This systematic review evaluates automatic segmentation methods for improving the accuracy and efficiency of MRI-based segmentation of pituitary adenomas and the gland itself. Methods: We reviewed 34 studies that employed automatic and semi-automatic segmentation methods. We extracted and synthesized data on segmentation techniques and performance metrics (such as Dice overlap scores). Results: The majority of reviewed studies utilized deep learning approaches, with U-Net-based models being the most prevalent. Automatic methods yielded Dice scores of 0.19--89.00\% for pituitary gland and 4.60--96.41\% for adenoma segmentation. Semi-automatic methods reported 80.00--92.10\% for pituitary gland and 75.90--88.36\% for adenoma segmentation. Conclusion: Most studies did not report important metrics such as MR field strength, age and adenoma size. Automated segmentation techniques such as U-Net-based models show promise, especially for adenoma segmentation, but further improvements are needed to achieve consistently good performance in small structures like the normal pituitary gland. Continued innovation and larger, diverse datasets are likely critical to enhancing clinical applicability.

A Deep Learning Based Method for Fast Registration of Cardiac Magnetic Resonance Images

Benjamin Graham

arxiv logopreprintJun 23 2025
Image registration is used in many medical image analysis applications, such as tracking the motion of tissue in cardiac images, where cardiac kinematics can be an indicator of tissue health. Registration is a challenging problem for deep learning algorithms because ground truth transformations are not feasible to create, and because there are potentially multiple transformations that can produce images that appear correlated with the goal. Unsupervised methods have been proposed to learn to predict effective transformations, but these methods take significantly longer to predict than established baseline methods. For a deep learning method to see adoption in wider research and clinical settings, it should be designed to run in a reasonable time on common, mid-level hardware. Fast methods have been proposed for the task of image registration but often use patch-based methods which can affect registration accuracy for a highly dynamic organ such as the heart. In this thesis, a fast, volumetric registration model is proposed for the use of quantifying cardiac strain. The proposed Deep Learning Neural Network (DLNN) is designed to utilize an architecture that can compute convolutions incredibly efficiently, allowing the model to achieve registration fidelity similar to other state-of-the-art models while taking a fraction of the time to perform inference. The proposed fast and lightweight registration (FLIR) model is used to predict tissue motion which is then used to quantify the non-uniform strain experienced by the tissue. For acquisitions taken from the same patient at approximately the same time, it would be expected that strain values measured between the acquisitions would have very small differences. Using this metric, strain values computed using the FLIR method are shown to be very consistent.

VHU-Net: Variational Hadamard U-Net for Body MRI Bias Field Correction

Xin Zhu

arxiv logopreprintJun 23 2025
Bias field artifacts in magnetic resonance imaging (MRI) scans introduce spatially smooth intensity inhomogeneities that degrade image quality and hinder downstream analysis. To address this challenge, we propose a novel variational Hadamard U-Net (VHU-Net) for effective body MRI bias field correction. The encoder comprises multiple convolutional Hadamard transform blocks (ConvHTBlocks), each integrating convolutional layers with a Hadamard transform (HT) layer. Specifically, the HT layer performs channel-wise frequency decomposition to isolate low-frequency components, while a subsequent scaling layer and semi-soft thresholding mechanism suppress redundant high-frequency noise. To compensate for the HT layer's inability to model inter-channel dependencies, the decoder incorporates an inverse HT-reconstructed transformer block, enabling global, frequency-aware attention for the recovery of spatially consistent bias fields. The stacked decoder ConvHTBlocks further enhance the capacity to reconstruct the underlying ground-truth bias field. Building on the principles of variational inference, we formulate a new evidence lower bound (ELBO) as the training objective, promoting sparsity in the latent space while ensuring accurate bias field estimation. Comprehensive experiments on abdominal and prostate MRI datasets demonstrate the superiority of VHU-Net over existing state-of-the-art methods in terms of intensity uniformity, signal fidelity, and tissue contrast. Moreover, the corrected images yield substantial downstream improvements in segmentation accuracy. Our framework offers computational efficiency, interpretability, and robust performance across multi-center datasets, making it suitable for clinical deployment.

Adaptive Mask-guided K-space Diffusion for Accelerated MRI Reconstruction

Qinrong Cai, Yu Guan, Zhibo Chen, Dong Liang, Qiuyun Fan, Qiegen Liu

arxiv logopreprintJun 23 2025
As the deep learning revolution marches on, masked modeling has emerged as a distinctive approach that involves predicting parts of the original data that are proportionally masked during training, and has demonstrated exceptional performance in multiple fields. Magnetic Resonance Imaging (MRI) reconstruction is a critical task in medical imaging that seeks to recover high-quality images from under-sampled k-space data. However, previous MRI reconstruction strategies usually optimized the entire image domain or k-space, without considering the importance of different frequency regions in the k-space This work introduces a diffusion model based on adaptive masks (AMDM), which utilizes the adaptive adjustment of frequency distribution based on k-space data to develop a hybrid masks mechanism that adapts to different k-space inputs. This enables the effective separation of high-frequency and low-frequency components, producing diverse frequency-specific representations. Additionally, the k-space frequency distribution informs the generation of adaptive masks, which, in turn, guide a closed-loop diffusion process. Experimental results verified the ability of this method to learn specific frequency information and thereby improved the quality of MRI reconstruction, providing a flexible framework for optimizing k-space data using masks in the future.

OpenMAP-BrainAge: Generalizable and Interpretable Brain Age Predictor

Pengyu Kan, Craig Jones, Kenichi Oishi

arxiv logopreprintJun 21 2025
Purpose: To develop an age prediction model which is interpretable and robust to demographic and technological variances in brain MRI scans. Materials and Methods: We propose a transformer-based architecture that leverages self-supervised pre-training on large-scale datasets. Our model processes pseudo-3D T1-weighted MRI scans from three anatomical views and incorporates brain volumetric information. By introducing a stem architecture, we reduce the conventional quadratic complexity of transformer models to linear complexity, enabling scalability for high-dimensional MRI data. We trained our model on ADNI2 $\&$ 3 (N=1348) and OASIS3 (N=716) datasets (age range: 42 - 95) from the North America, with an 8:1:1 split for train, validation and test. Then, we validated it on the AIBL dataset (N=768, age range: 60 - 92) from Australia. Results: We achieved an MAE of 3.65 years on ADNI2 $\&$ 3 and OASIS3 test set and a high generalizability of MAE of 3.54 years on AIBL. There was a notable increase in brain age gap (BAG) across cognitive groups, with mean of 0.15 years (95% CI: [-0.22, 0.51]) in CN, 2.55 years ([2.40, 2.70]) in MCI, 6.12 years ([5.82, 6.43]) in AD. Additionally, significant negative correlation between BAG and cognitive scores was observed, with correlation coefficient of -0.185 (p < 0.001) for MoCA and -0.231 (p < 0.001) for MMSE. Gradient-based feature attribution highlighted ventricles and white matter structures as key regions influenced by brain aging. Conclusion: Our model effectively fused information from different views and volumetric information to achieve state-of-the-art brain age prediction accuracy, improved generalizability and interpretability with association to neurodegenerative disorders.
Page 6 of 16157 results
Show
per page

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.