Back to all papers

Human subject study of a transmission-aided attenuation correction for precision PET neuroimaging.

Authors

Lotfimarangloo S,Rahman ST,Park MA,Fei B,Badawi RD,Bowen SL

Affiliations (4)

  • Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA.
  • Department of Bioengineering, University of Texas at Dallas, Richardson, TX, USA.
  • Department of Radiology, University of California Davis Medical Center, Sacramento, CA, USA.
  • Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA. [email protected].

Abstract

PET data-driven attenuation correction (AC) methods, including deep learning, are attractive options for quantitative brain imaging on CT-less brain PET systems and low-dose PET/CT. However, current schemes have performance and practical limitations. We previously developed a CT-less transmission-aided AC that combines coincidences from a weak positron source, and the patient, to estimate attenuation with physics alone. In this work, we aim to optimize and assess this new AC method during human [<sup>18</sup>F]FDG neuroimaging on whole-body PET/CT. Our approach, TRansmission-aided μ-map reconstruction (TRU) AC, includes 1) a low-profile and physically fixed transmission source filled with ~ 14 MBq of <sup>18</sup>F, 2) a modified maximum likelihood reconstruction of attenuation and activity algorithm, and 3) scatter corrections using the exam data alone. We imaged N = 5 patients with the transmission source, immediately after their clinical [<sup>18</sup>F]FDG PET/CT. The clinically-consistent protocol included a CT and 10-minute brain-focused PET exam. Using this 10 minutes of patient PET data alone, radiotracer images were reconstructed with the vendor's algorithm and TRU-AC or CT-AC (reference standard), with all else matched. For quantitative analysis, we placed brain-structure volumes of interest with an atlas, and computed error in mean standardized uptake values of TRU-AC relative to CT-AC. TRU-AC PET showed qualitatively strong agreement with CT-AC. For the VOI analysis, absolute relative error in standardized uptake values for TRU-AC was within 3.6%, across all brain structures and patients. Normalized root mean square error of activity bias for TRU-AC was 1.8%, and voxel-wise noise in the cerebellum showed a very minor increase of 0.2%. Bland-Altman analysis demonstrated that TRU-AC and CT-AC have statistically significant agreement, assuming a maximum allowed difference of ± 5%. TRU-AC enables quantitative PET for human neuroimaging. This approach may particularly benefit exams where deep learning-based AC schemes show reduced performance, including those focused on radiotracer development, new patient cohorts, and/or pathologies that often lack sufficient training data.

Topics

Journal Article

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.