Back to all papers

Diagnostic performance of artificial intelligence for detecting peritoneal and small bowel dissemination in epithelial ovarian cancer using preoperative contrast-enhanced CT imaging.

March 23, 2026pubmed logopapers

Authors

Kim R,Seki T,Noda K,Yoshida K,Yokosu K,Hamada R,Habuchi E,Takahashi M,Takano H,Okamoto A

Affiliations (4)

  • Department of Obstetrics and Gynecology, The Jikei University School of Medicine, 3-25-8 Nishi-Shinbashi, Minato-Ku, Tokyo, 105-8461, Japan.
  • Department of Obstetrics and Gynecology, The Jikei University School of Medicine, 3-25-8 Nishi-Shinbashi, Minato-Ku, Tokyo, 105-8461, Japan. [email protected].
  • SIOS Technology, Inc., Tokyo, Japan.
  • Department of Otorhinolaryngology, The Jikei University School of Medicine, Tokyo, 105-8461, Japan.

Abstract

In epithelial ovarian cancer (EOC), accurate assessment of the lesions is crucial for determining the appropriate treatment strategy. We evaluated artificial intelligence (AI) for detecting peritoneal and small bowel dissemination in EOC using preoperative contrast-enhanced computed tomography (CT). We retrospectively analyzed 227 patients (254 CT scans) with histologically confirmed ovarian, fallopian tube, or peritoneal carcinoma who underwent surgery between October 2019 and December 2024 at two affiliated institutions. The mean patient age was 56.6 years. The FIGO stage was early in 118 cases and advanced in 136 cases. Histology included serous (n = 123) and non-serous (n = 131). The mean CA125 level and peritoneal cancer index (PCI) score were 2,243.9 U/mL and 5.8, respectively. Two AI models were developed: one for peritoneal dissemination (P-Model) and one for small bowel dissemination (SB-Model). Diagnostic performance was evaluated by sensitivity, specificity, and accuracy. For the P-Model, clinical factors were compared between high- and low-accuracy groups. The P-Model achieved 68.75% sensitivity, 85.84% specificity, and 77.30% accuracy; the SB-Model, 86.40%, 77.47%, and 81.93%, respectively. Low AI accuracy was linked to ascites volume, CA125 level, and PCI score. AI-based analysis of preoperative CT demonstrated favorable diagnostic performance for detecting dissemination in patients with EOC. The online version contains supplementary material available at 10.1038/s41598-026-41728-4.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.