Back to all papers

PHIVE: A physics-informed variational encoder enables rapid spectral fitting of brain metabolite mapping at 7T.

March 3, 2026pubmed logopapers

Authors

Shamaei A,Buchali A,Niess E,Hingerl L,Strasser B,Osburg A,Eckstein K,Bogner W,Motyka S

Affiliations (7)

  • Electrical and Software Engineering, University of Calgary, Calgary, AB, Canada; Hotchkiss Brain Institute, University of Calgary, Calgary, AB, Canada.
  • Massive Portraits, Vancouver, BC, Canada.
  • Department of Biomedical Imaging and Image-guided Therapy, Radiology and Nuclear Medicine, Medical University of Vienna, Vienna, Austria.
  • Department of Biomedical Imaging and Image-guided Therapy, Radiology and Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Comprehensive Center for AI in Medicine (CAIM), Medical University of Vienna, Vienna, Austria.
  • Department of Biomedical Imaging and Image-guided Therapy, Radiology and Nuclear Medicine, Medical University of Vienna, Vienna, Austria; School of Electrical Engineering and Computer Science, The University of Queensland, St Lucia, Australia.
  • Department of Biomedical Imaging and Image-guided Therapy, Radiology and Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for MR Imaging Biomarker Development, Vienna, Austria; Comprehensive Center for AI in Medicine (CAIM), Medical University of Vienna, Vienna, Austria. Electronic address: [email protected].
  • Department of Biomedical Imaging and Image-guided Therapy, Radiology and Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Christian Doppler Laboratory for MR Imaging Biomarker Development, Vienna, Austria; Comprehensive Center for AI in Medicine (CAIM), Medical University of Vienna, Vienna, Austria.

Abstract

Magnetic Resonance Spectroscopic Imaging (MRSI) enables non-invasive mapping of brain metabolite concentrations but remains computationally intensive and challenging due to a low signal-to-noise ratio (SNR) and overlapping spectral features. Traditional spectral fitting methods, such as LCModel, are time-consuming and often lack comprehensive uncertainty quantification. In this study, we propose Physics-Informed Variational Encoder (PHIVE), a novel deep learning framework that integrates physics-based priors into a variational autoencoder architecture for rapid and accurate metabolite quantification. PHIVE enables simultaneous estimation of metabolite concentrations and uncertainty metrics, including Cramér-Rao Lower Bound (CRLB), aleatoric, and epistemic uncertainties. PHIVE is evaluated on whole-brain MRSI data from 7T acquisitions of healthy controls and multiple sclerosis (MS) patients. The method achieved comparable accuracy to LCModel for key metabolites, such as Total N-acetylaspartate (tNAA), Glutamate-Glutamine complex (Glx), and Myo-inositol (mIns) while demonstrating a six-order-of-magnitude reduction in computational time (6 ms per dataset). Uncertainty quantification highlighted PHIVE's robustness in regions with low SNR. Additionally, a conditional baseline modeling approach is introduced, enabling dynamic flexibility in spectral baseline estimation during inference time. These results suggest that PHIVE offers a fast, reliable, and interpretable solution for high-resolution metabolite quantification, paving the way for real-time MRSI applications in clinical and research settings. Future work will focus on expanding its validation across diverse datasets and investigating its utility in longitudinal and multi-center studies. Our code is available at https://github.com/amirshamaei/PHIVE.

Topics

Journal Article

Ready to Sharpen Your Edge?

Subscribe to join 11k+ peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.