Predicting hepatocellular carcinoma response to TACE: A machine learning study based on 2.5D CT imaging and deep features analysis.
Authors
Affiliations (4)
Affiliations (4)
- Department of Radiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China; Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang, Guizhou, China.
- Department of Radiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China.
- Department of Radiology, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang, Guizhou, China.
- Department of Radiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China. Electronic address: [email protected].
Abstract
Prior to the commencement of treatment, it is essential to establish an objective method for accurately predicting the prognosis of patients with hepatocellular carcinoma (HCC) undergoing transarterial chemoembolization (TACE). In this study, we aimed to develop a machine learning (ML) model to predict the response of HCC patients to TACE based on CT images analysis. Public dataset from The Cancer Imaging Archive (TCIA), uploaded in August 2022, comprised a total of 105 cases, including 68 males and 37 females. The external testing dataset was collected from March 1, 2019 to July 1, 2022, consisting of total of 26 patients who underwent TACE treatment at our institution and were followed up for at least 3 months after TACE, including 22 males and 4 females. The public dataset was utilized for ResNet50 transfer learning and ML model construction, while the external testing dataset was used for model performance evaluation. All CT images with the largest lesions in axial, sagittal, and coronal orientations were selected to construct 2.5D images. Pre-trained ResNet50 weights were adapted through transfer learning to serve as a feature extractor to derive deep features for building ML models. Model performance was assessed using area under the curve (AUC), accuracy, F1-Score, confusion matrix analysis, decision curves, and calibration curves. The AUC values for the external testing dataset were 0.90, 0.90, 0.91, and 0.89 for random forest classifier (RFC), support vector classifier (SVC), logistic regression (LR), and extreme gradient boosting (XGB), respectively. The accuracy values for the external testing dataset were 0.79, 0.81, 0.80, and 0.80 for RFC, SVC, LR, and XGB, respectively. The F1-score values for the external testing dataset were 0.75, 0.77, 0.78, and 0.79 for RFC, SVC, LR, and XGB, respectively. The ML model constructed using deep features from 2.5D images has the potential to be applied in predicting the prognosis of HCC patients following TACE treatment.