Quantitative image quality metrics enable resource-efficient quality control of clinically applied AI-based reconstructions in MRI.

Authors

White OA,Shur J,Castagnoli F,Charles-Edwards G,Whitcher B,Collins DJ,Cashmore MTD,Hall MG,Thomas SA,Thompson A,Harrison CA,Hopkinson G,Koh DM,Winfield JM

Affiliations (5)

  • MRI Unit, The Royal Marsden NHS Foundation Trust, London, UK. [email protected].
  • Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, UK. [email protected].
  • MRI Unit, The Royal Marsden NHS Foundation Trust, London, UK.
  • Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, UK.
  • National Physical Laboratory, Teddington, UK.

Abstract

AI-based MRI reconstruction techniques improve efficiency by reducing acquisition times whilst maintaining or improving image quality. Recent recommendations from professional bodies suggest centres should perform quality assessments on AI tools. However, monitoring long-term performance presents challenges, due to model drift or system updates. Radiologist-based assessments are resource-intensive and may be subjective, highlighting the need for efficient quality control (QC) measures. This study explores using image quality metrics (IQMs) to assess AI-based reconstructions. 58 patients undergoing standard-of-care rectal MRI were imaged using AI-based and conventional T2-weighted sequences. Paired and unpaired IQMs were calculated. Sensitivity of IQMs to detect retrospective perturbations in AI-based reconstructions was assessed using control charts, and statistical comparisons between the four MR systems in the evaluation were performed. Two radiologists evaluated the image quality of the perturbed images, giving an indication of their clinical relevance. Paired IQMs demonstrated sensitivity to changes in AI-reconstruction settings, identifying deviations outside ± 2 standard deviations of the reference dataset. Unpaired metrics showed less sensitivity. Paired IQMs showed no difference in performance between 1.5 T and 3 T systems (p > 0.99), whilst minor but significant (p < 0.0379) differences were noted for unpaired IQMs. IQMs are effective for QC of AI-based MR reconstructions, offering resource-efficient alternatives to repeated radiologist evaluations. Future work should expand this to other imaging applications and assess additional measures.

Topics

Journal Article

Ready to Sharpen Your Edge?

Join hundreds of your peers who rely on RadAI Slice. Get the essential weekly briefing that empowers you to navigate the future of radiology.

We respect your privacy. Unsubscribe at any time.